Literature DB >> 16901608

A new tracheal tube and methods to facilitate ventilation and placement in emergency airway management.

Huafeng Wei1.   

Abstract

The "jet endotracheal tube" (JET) has been designed to facilitate emergency intubation in apnoeic or paralyzed patients with a difficult airway. We investigated the efficiency of jet ventilation to maintain adequate oxygenation and ventilation using the initially designed JET, either with its distal tip positioned above vocal cord and pointed directly at or 45 degrees to the right of the vocal cord opening midline in 10 adult paralyzed pigs. The effectiveness of using end tidal carbon dioxide pressure (PetCO(2)), chest rise and breath sounds to facilitate tracheal placement of the JET blindly in a simulated difficult airway was studied. All complications of using the JET were noted. Jet ventilation with the distal tip of the JET pointed directly at, not 45 degrees to the right of vocal cord opening midline, provides adequate oxygenation and ventilation during intubation. In a simulated difficult airway, PetCO(2), chest rise and breath sounds were all effective methods to assist placement of the JET blindly, and the combination of all three methods works the best. No serious complications were detected with the use of the JET. Our results suggest that a correctly positioned JET guided by monitoring PetCO(2), chest rise and breath sound provides adequate oxygenation and ventilation during intubation in apnoeic pigs, and facilitates the intubation blindly in a simulated difficult airway. No serious complications were observed using the JET in this study. In patients requiring emergency intubation, a JET with PetCO(2) monitoring catheter and the instructions for use may be a useful addition to the airway management devices.

Entities:  

Mesh:

Year:  2006        PMID: 16901608     DOI: 10.1016/j.resuscitation.2006.01.021

Source DB:  PubMed          Journal:  Resuscitation        ISSN: 0300-9572            Impact factor:   5.262


  6 in total

1.  Supraglottic jet oxygenation and ventilation-assisted fibre-optic bronchoscope intubation in patients with difficult airways.

Authors:  Caineng Wu; Jianqi Wei; Qingyun Cen; Xuefan Sha; Qingxiang Cai; Wuhua Ma; Ying Cao
Journal:  Intern Emerg Med       Date:  2016-09-14       Impact factor: 3.397

2.  Laryngoscope and a new tracheal tube assist lightwand intubation in difficult airways due to unstable cervical spine.

Authors:  Cai-neng Wu; Wu-hua Ma; Jian-qi Wei; Hua-feng Wei; Qing-yun Cen; Qing-xiang Cai; Ying Cao
Journal:  PLoS One       Date:  2015-03-24       Impact factor: 3.240

3.  Supraglottic jet oxygenation and ventilation saved a patient with 'cannot intubate and cannot ventilate' emergency difficult airway.

Authors:  Qiaoyun Li; Ping Xie; Benjun Zha; ZhiYun Wu; Huafeng Wei
Journal:  J Anesth       Date:  2016-11-15       Impact factor: 2.078

4.  Supraglottic jet oxygenation and ventilation assisted fiberoptic intubation in a paralyzed patient with morbid obesity and obstructive sleep apnea: a case report.

Authors:  Hansheng Liang; Yuantao Hou; Huafeng Wei; Yi Feng
Journal:  BMC Anesthesiol       Date:  2019-03-20       Impact factor: 2.217

5.  Supraglottic jet oxygenation and ventilation for obese patients under intravenous anesthesia during hysteroscopy: a randomized controlled clinical trial.

Authors:  Hansheng Liang; Yuantao Hou; Liang Sun; Qingyue Li; Huafeng Wei; Yi Feng
Journal:  BMC Anesthesiol       Date:  2019-08-14       Impact factor: 2.217

6.  Supraglottic jet oxygenation and ventilation reduces desaturation during bronchoscopy under moderate to deep sedation with propofol and remifentanil: A randomised controlled clinical trial.

Authors:  Benjun Zha; Zhiyun Wu; Ping Xie; Huaping Xiong; Li Xu; Huafeng Wei
Journal:  Eur J Anaesthesiol       Date:  2021-03-01       Impact factor: 4.183

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.