Literature DB >> 16898463

Three dimensional radiation dosimetry in lung-equivalent regions by use of a radiation sensitive gel foam: proof of principle.

Yves De Deene1, Koen Vergote, Carolien Claeys, Carlos De Wagter.   

Abstract

A polymer hydrogel foam is proposed as a potential three dimensional experimental dosimeter for radiation treatment verification in low-density tissue such as the lung. A gel foam is created by beating a radiation sensitive polymer gel mixture in an anoxic atmosphere. The mass density of the gel foam is in the order of 0.25-0.35 kg/dm3. Both nuclear magnetic resonance (NMR) spin-spin relaxation rate (R2) and magnetization transfer ratio (MTR) have been used to map the dose distribution from the gel dosimeter. It is found that MTR has significant advantages compared to R2 for mapping the dose distribution in the polymer gel foam dosimeters. The magnetization transfer ratio is found to be less dependent on the density and microstructure of the gel foam dosimeter while spin-spin relaxation dispersion has been observed making the spin-spin relaxation rate dependent on the interecho time interval. Optical microscopy reveals a microstructure that shows great similarity with human lung tissue. It is also shown how NMR hydrogen proton density measurements can be used to map the density distributions in gel dosimeters.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16898463     DOI: 10.1118/1.2208939

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  4 in total

Review 1.  Polymer gel dosimetry.

Authors:  C Baldock; Y De Deene; S Doran; G Ibbott; A Jirasek; M Lepage; K B McAuley; M Oldham; L J Schreiner
Journal:  Phys Med Biol       Date:  2010-02-11       Impact factor: 3.609

2.  Magnetization transfer proportion: a simplified measure of dose response for polymer gel dosimetry.

Authors:  Heather M Whitney; Daniel F Gochberg; John C Gore
Journal:  Phys Med Biol       Date:  2008-11-26       Impact factor: 3.609

3.  Does nitrogen gas bubbled through a low density polymer gel dosimeter solution affect the polymerization process?

Authors:  Daryoush Shahbazi-Gahrouei; Mehrdad Gholami; Tayyeb Allahverdi Pourfallah; Mohammad Keshtkar
Journal:  Adv Biomed Res       Date:  2015-05-11

Review 4.  Radiation Dosimetry by Use of Radiosensitive Hydrogels and Polymers: Mechanisms, State-of-the-Art and Perspective from 3D to 4D.

Authors:  Yves De Deene
Journal:  Gels       Date:  2022-09-19
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.