Literature DB >> 16891193

Impact of the cardiac troponin testing algorithm on excessive and inappropriate troponin test requests.

Qing H Meng1, Shiming Zhu, Cheryl Booth, Linda Stevens, Bonnie Bertsch, Mabood Qureshi, Jawahar Kalra.   

Abstract

Cardiac troponin (cTn) is a key biomarker for the assessment of myocardial injury, but overutilization of this test has increased workload and costs. We developed and implemented an algorithm to eliminate excessive utilization. Significant reduction was observed after the implementation of the algorithm in total cTnI requests (29.9%; P = .007), requests from outpatient clinics (70.7%; P = .003), and other wards (42.8%; P = .003). Stat requests, the number of third requests, and more than 3 requests per patient were reduced significantly by 42.8% (P = .004), 35.8% (P = .003), and 49.4% (P = .008), respectively. The test and labor costs each were reduced by 29.9% (P = .007 for each). There was no significant change in cTnI orders from emergency and critical care departments. The cTnI testing algorithm reduced unnecessary orders for cTnI tests with no reduction in meeting patients'critical needs. Reduction in unnecessary and inappropriate requests reduces labor and test costs.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16891193     DOI: 10.1309/GK9B-FAB1-Y5LN-BWU1

Source DB:  PubMed          Journal:  Am J Clin Pathol        ISSN: 0002-9173            Impact factor:   2.493


  4 in total

1.  The Veracity of Troponin Test Requests for Patients Presenting to the Emergency Department with Chest Pain; a Clinical Audit.

Authors:  Anita Sabzghabaei; Majid Shojaee; Marzieh Amiri; Neda Akhoundzadeh; Saeed Safari
Journal:  Adv J Emerg Med       Date:  2017-10-18

2.  Evaluation of Dual Marker Approach Using Heart-Type Fatty Acid Binding Protein and High Sensitivity Troponin-I as an Alternative to Serial Sampling for Diagnosis of Acute Myocardial Infarction.

Authors:  Manish Raj Kulshrestha; Apurva Raj; Vandana Tiwari; Subrat Chandra; Bhuwan Chandra Tiwari; Ashish Jha
Journal:  EJIFCC       Date:  2022-04-11

3.  Reducing excess cardiac biomarker testing at an academic medical center.

Authors:  Marc R Larochelle; Amy M Knight; Hardin Pantle; Stefan Riedel; Jeffrey C Trost
Journal:  J Gen Intern Med       Date:  2014-06-28       Impact factor: 5.128

Review 4.  Reducing Test Utilization in Hospital Settings: A Narrative Review.

Authors:  Renuka S Bindraban; Maarten J Ten Berg; Christiana A Naaktgeboren; Mark H H Kramer; Wouter W Van Solinge; Prabath W B Nanayakkara
Journal:  Ann Lab Med       Date:  2018-09       Impact factor: 3.464

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.