Literature DB >> 16890868

Forearm cephalic vein cross-sectional area changes at incremental congestion pressures: towards a standardized and reproducible vein mapping protocol.

R Nils Planken1, Xavier H Keuter, Alfons G Kessels, Arnold P Hoeks, Tim Leiner, Jan H Tordoir.   

Abstract

OBJECTIVES: Duplex ultrasonography assessment of superficial forearm veins is frequently used before a hemodialysis arteriovenous fistula (AVF) is created. There is, however, no standardized preoperative duplex ultrasonography protocol. This study assessed B-mode image analysis reproducibility and reproducibility of repeated forearm superficial venous diameter measurements on different days at different venous congestion pressures (VCPs).
METHODS: Diameters were determined using B-mode ultrasonography in 10 healthy male volunteers on days 1 and 14 at incremental VCP values (10 to 80 mm Hg). Intra- and interobserver agreement was assessed for B-mode image analysis by calculating interclass correlation coefficients (ICC). Reproducibility of repeated diameter measurements (maximum and minimum diameter at days 1 and 14), cross-sectional area size increase, and shape change due to incremental VCPs were determined by calculating ICC values.
RESULTS: Analysis of intraobserver agreement of B-mode image interpretation yielded ICC values of 0.97 (95% confidence interval [CI], 0.94 to 0.99) and 0.97 (95% CI, 0.96 to 0.99) for determination of maximum and minimum diameters, respectively. Interobserver agreement analysis yielded ICC values of 0.95 (95% CI, 0.92 to 0.97) and 0.96 (95% CI, 0.96 to 0.99) for determination of maximum and minimum diameters, respectively. Reproducibility of repeated diameter measurements on days 1 and 14 improved substantially at incremental VCP values, with best reproducibility at VCPs >40 mm Hg. Repeated determination of cross-sectional area size increase and shape change due to VCP increase from 10 to 80 mm Hg yielded ICC values of 0.49 (95% CI, 0.19 to 1.00) and 0.09 (95% CI, 0.00 to 0.92), respectively. Maximum and minimum diameters as well as cross-sectional area size increased significantly (P < .01) due to VCP increase during both sessions. Cross-sectional area shape changed significantly (P < .01) due to VCP increase during both sessions.
CONCLUSIONS: Diameter measurements on B-mode images are largely observer independent. Superficial venous cross-sectional area shape is noncircular, and cross-sectional area size depends on VCP. Both maximum and minimum venous diameters should be determined at VCPs >40 mm Hg to attain the best reproducibility. Further studies are needed to determine whether a standardized preoperative vein mapping protocol can reduce AVF nonmaturation rates.

Entities:  

Mesh:

Year:  2006        PMID: 16890868     DOI: 10.1016/j.jvs.2006.04.038

Source DB:  PubMed          Journal:  J Vasc Surg        ISSN: 0741-5214            Impact factor:   4.268


  8 in total

1.  Can we make the basilic vein larger? maneuvers to facilitate ultrasound guided peripheral intravenous access: a prospective cross-sectional study.

Authors:  Simon A Mahler; Greta Massey; Liliana Meskill; Hao Wang; Thomas C Arnold
Journal:  Int J Emerg Med       Date:  2011-08-25

2.  Venous elastography: validation of a novel high-resolution ultrasound method for measuring vein compliance using finite element analysis.

Authors:  Rohan Biswas; Prashant Patel; Dae W Park; Thomas J Cichonski; Michael S Richards; Jonathan M Rubin; James Hamilton; William F Weitzel
Journal:  Semin Dial       Date:  2010 Jan-Feb       Impact factor: 3.455

3.  Non-invasive estimation of vascular compliance and distensibility in the arm vessels: a novel ultrasound-based protocol.

Authors:  Sara Cappelletti; Alessandro Caimi; Alice Caldiroli; Irene Baroni; Emiliano Votta; Stefania A Riboldi; Massimiliano M Marrocco-Trischitta; Alberto Redaelli; Francesco Sturla
Journal:  Quant Imaging Med Surg       Date:  2022-07

Review 4.  Current techniques for assessment of upper extremity vasculature prior to hemodialysis vascular access creation.

Authors:  R N Planken; J H M Tordoir; L E M Duijm; M W de Haan; T Leiner
Journal:  Eur Radiol       Date:  2007-05-08       Impact factor: 5.315

5.  Patient-specific computational modeling of upper extremity arteriovenous fistula creation: its feasibility to support clinical decision-making.

Authors:  Aron S Bode; Wouter Huberts; E Marielle H Bosboom; Wilco Kroon; Wim P M van der Linden; R Nils Planken; Frans N van de Vosse; Jan H M Tordoir
Journal:  PLoS One       Date:  2012-04-04       Impact factor: 3.240

6.  Immersion ultrasonography improves the repeatability of cephalic vein diameter measurements for inexperienced operators.

Authors:  Zhijun Zhang; Shu He; Hui Wang; Yu Zhong; Hairong Zou; Xuan Gao
Journal:  Ren Fail       Date:  2022-12       Impact factor: 3.222

7.  The benefit of non contrast-enhanced magnetic resonance angiography for predicting vascular access surgery outcome: a computer model perspective.

Authors:  Maarten A G Merkx; Wouter Huberts; E Mariëlle H Bosboom; Aron S Bode; Javier Oliván Bescós; Jan H M Tordoir; Marcel Breeuwer; Frans N van de Vosse
Journal:  PLoS One       Date:  2013-02-04       Impact factor: 3.240

8.  Reproducibility of the SPI-US protocol for ultrasound diameter measurements of the Posterior Circumflex Humeral Artery and Deep Brachial Artery: an inter-rater reliability study.

Authors:  Daan van de Pol; Sena Alaeikhanehshir; P Paul F M Kuijer; Aart Terpstra; Marja J C Pannekoek-Hekman; R Nils Planken; Mario Maas
Journal:  Eur Radiol       Date:  2015-12-10       Impact factor: 5.315

  8 in total