Literature DB >> 16886867

A generic camera model and calibration method for conventional, wide-angle, and fish-eye lenses.

Juho Kannala1, Sami S Brandt.   

Abstract

Fish-eye lenses are convenient in such applications where a very wide angle of view is needed, but their use for measurement purposes has been limited by the lack of an accurate, generic, and easy-to-use calibration procedure. We hence propose a generic camera model, which is suitable for fish-eye lens cameras as well as for conventional and wide-angle lens cameras, and a calibration method for estimating the parameters of the model. The achieved level of calibration accuracy is comparable to the previously reported state-of-the-art.

Mesh:

Year:  2006        PMID: 16886867     DOI: 10.1109/TPAMI.2006.153

Source DB:  PubMed          Journal:  IEEE Trans Pattern Anal Mach Intell        ISSN: 0098-5589            Impact factor:   6.226


  23 in total

1.  Quantitative evaluation for accumulative calibration error and video-CT registration errors in electromagnetic-tracked endoscopy.

Authors:  Sheena Xin Liu; Luis F Gutiérrez; Doug Stanton
Journal:  Int J Comput Assist Radiol Surg       Date:  2010-08-17       Impact factor: 2.924

2.  Overlay visualization in endoscopic ENT surgery.

Authors:  Christian Winne; Martin Khan; Fabian Stopp; Emanuel Jank; Erwin Keeve
Journal:  Int J Comput Assist Radiol Surg       Date:  2010-06-26       Impact factor: 2.924

3.  A novel noncontact detection method of surgeon's operation for a master-slave endovascular surgery robot.

Authors:  Yan Zhao; Huiming Xing; Shuxiang Guo; Yuxin Wang; Jinxin Cui; Youchun Ma; Yu Liu; Xinke Liu; Junqiang Feng; Youxiang Li
Journal:  Med Biol Eng Comput       Date:  2020-02-19       Impact factor: 2.602

4.  Feasibility of obtaining quantitative 3-dimensional information using conventional endoscope: a pilot study.

Authors:  Jong Jin Hyun; Hoon Jai Chun; Bora Keum; Yeon Seok Seo; Yong Sik Kim; Yoon Tae Jeen; Hong Sik Lee; Soon Ho Um; Chang Duck Kim; Ho Sang Ryu; Jong-Wook Lim; Dong-Gi Woo; Young-Joong Kim; Myo-Taeg Lim
Journal:  Clin Endosc       Date:  2012-08-22

5.  3D Vision by Using Calibration Pattern with Inertial Sensor and RBF Neural Networks.

Authors:  Erkan Beṣdok
Journal:  Sensors (Basel)       Date:  2009-06-11       Impact factor: 3.576

6.  Omnidirectional underwater camera design and calibration.

Authors:  Josep Bosch; Nuno Gracias; Pere Ridao; David Ribas
Journal:  Sensors (Basel)       Date:  2015-03-12       Impact factor: 3.576

7.  Towards Camera-LIDAR Fusion-Based Terrain Modelling for Planetary Surfaces: Review and Analysis.

Authors:  Affan Shaukat; Peter C Blacker; Conrad Spiteri; Yang Gao
Journal:  Sensors (Basel)       Date:  2016-11-20       Impact factor: 3.576

8.  GPS-supported visual SLAM with a rigorous sensor model for a panoramic camera in outdoor environments.

Authors:  Yun Shi; Shunping Ji; Zhongchao Shi; Yulin Duan; Ryosuke Shibasaki
Journal:  Sensors (Basel)       Date:  2012-12-21       Impact factor: 3.576

9.  A master-slave surveillance system to acquire panoramic and multiscale videos.

Authors:  Yu Liu; Shiming Lai; Chenglin Zuo; Hao Shi; Maojun Zhang
Journal:  ScientificWorldJournal       Date:  2014-03-03

10.  Design of a device for sky light polarization measurements.

Authors:  Yujie Wang; Xiaoping Hu; Junxiang Lian; Lilian Zhang; Zhiwen Xian; Tao Ma
Journal:  Sensors (Basel)       Date:  2014-08-14       Impact factor: 3.576

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.