Literature DB >> 16886236

Rendering in fetal cardiac scanning: the intracardiac septa and the coronal atrioventricular valve planes.

S Yagel1, A Benachi, D Bonnet, Y Dumez, D Hochner-Celnikier, S M Cohen, D V Valsky, L Fermont.   

Abstract

OBJECTIVE: In this study we aimed to apply spatio-temporal image correlation (STIC) rendering to visualize the virtual planes of the interventricular and interatrial septa (IVS, IAS) as well as the atrioventricular (AV) annuli plane just distal to the semilunar valves (coronal atrioventricular (CAV) plane) in normal and pathological fetal hearts, to ascertain whether these planes add to fetal cardiac examination.
METHODS: Unselected gravidae presenting for anatomy scan or patients referred for fetal echocardiography in the second and third trimesters of pregnancy with suspected or diagnosed cardiac malformation were scanned using the five planes technique with the STIC modality to obtain cardiac volume sets for each patient. Rendering capabilities were employed to obtain the 'virtual planes' to evaluate the IVS, IAS, AV annuli, and size and alignment of the great vessels.
RESULTS: A total of 136 normal scans were performed to establish a learning curve for STIC acquisition and post-processing rendering and analysis. An additional 35 cases with cardiac anomalies were accrued. In 131/136 (96.3%) normal scans the IAS and IVS were visualized successfully, while in 127/136 (93.4%) normal fetuses the CAV plane was successfully visualized. In 13 anomalous cases the IVS plane improved ventricular septal defect (VSD) evaluation, and in four the IAS plane contributed to foramen ovale evaluation. The modality improved visualization of the septa and the assessment of the defects, as well as the foramen ovale flap and pattern of movement of the foramen ovale. In five cases the CAV plane improved evaluation of the alignment of the major vessels in relation to the AV annuli, and in three the evaluation of the semilunar valves, with or without malalignment of the great vessels.
CONCLUSIONS: Rendering STIC technology allows the visualization of virtual planes (IAS, IVS, AV annuli-CAV plane), which can clarify our understanding of anatomical defects and may improve communication with the management team and family. Copyright 2006 ISUOG. Published by John Wiley & Sons, Ltd.

Entities:  

Mesh:

Year:  2006        PMID: 16886236     DOI: 10.1002/uog.2843

Source DB:  PubMed          Journal:  Ultrasound Obstet Gynecol        ISSN: 0960-7692            Impact factor:   7.299


  7 in total

1.  The benefits of 3D-4D fetal echocardiography.

Authors:  Cringu Ionescu
Journal:  Maedica (Buchar)       Date:  2010-01

2.  Simple targeted arterial rendering (STAR) technique: a novel and simple method to visualize the fetal cardiac outflow tracts.

Authors:  L Yeo; R Romero; C Jodicke; S K Kim; J M Gonzalez; G Oggè; W Lee; J P Kusanovic; E Vaisbuch; S Hassan
Journal:  Ultrasound Obstet Gynecol       Date:  2011-03-02       Impact factor: 7.299

3.  Consistent reconstruction of 4D fetal heart ultrasound images to cope with fetal motion.

Authors:  Christine Tanner; Barbara Flach; Céline Eggenberger; Oliver Mattausch; Michael Bajka; Orcun Goksel
Journal:  Int J Comput Assist Radiol Surg       Date:  2017-06-20       Impact factor: 2.924

Review 4.  Three- and four-dimensional ultrasound in fetal echocardiography: an up-to-date overview.

Authors:  B M E Adriaanse; J M G van Vugt; M C Haak
Journal:  J Perinatol       Date:  2016-03-10       Impact factor: 2.521

5.  Evaluation of fetal foramen ovale blood flow by pulsed Doppler ultrasonography combined with spatiotemporal image correlation : To define the normal reference range of fetal foramen ovale blood volume for each gestational age: a cross-sectional study.

Authors:  Wenjuan Tang; Yuanchen Luo; Shi Zeng; Jiawei Zhou; Ganqiong Xu; Jianwen Yang
Journal:  Cardiovasc Ultrasound       Date:  2021-05-05       Impact factor: 2.062

6.  Application of spatio-temporal image correlation technology in the diagnosis of fetal cardiac abnormalities.

Authors:  Yihua He; Junlan Wang; Xiaoyan Gu; Ye Zhang; Jiancheng Han; Xiaowei Liu; Zhian Li
Journal:  Exp Ther Med       Date:  2013-04-09       Impact factor: 2.447

7.  Performance of different scan protocols of fetal echocardiography in the diagnosis of fetal congenital heart disease: a systematic review and meta-analysis.

Authors:  Yifei Li; Yimin Hua; Jie Fang; Chuan Wang; Lina Qiao; Chaomin Wan; Dezhi Mu; Kaiyu Zhou
Journal:  PLoS One       Date:  2013-06-04       Impact factor: 3.240

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.