Literature DB >> 16885513

Distraction forces on repaired bucket-handle lesions in the medial meniscus.

Roland Becker1, Olaf Brettschneider, Karl-Heinz Gröbel, Rüdiger von Versen, Christian Stärke.   

Abstract

BACKGROUND: Numerous studies have investigated the biomechanical properties of meniscal repair techniques. One of the most commonly discussed parameters is the failure load in the axis of insertion, although little is known about the distraction forces actually occurring at repaired bucket-handle lesions. HYPOTHESIS: There are clinically relevant distraction forces on repaired meniscus bucket-handle lesions. STUDY
DESIGN: Controlled laboratory study.
METHODS: Meniscus bucket-handle lesions were created and repaired in human cadaveric knees with a vertical suture made from a braided steel wire. A small-sized load sensor was connected to the wire at the periphery of the meniscus. The distraction forces acting on the lesion were measured at different knee joint angles (0 degrees -120 degrees of flexion) with internal and external rotation and with and without weight loading. Forces in excess of 10 N were considered to have clinical relevance.
RESULTS: Mean forces on the meniscus repair ranged from 1.64 to 4.72 N. Irrespective of the modalities (ie, different flexion angles, weight load, direction of rotation), it was found that the forces were well below the cutoff value of 10 N (P < .01). Increasing flexion angles generally did not cause an increase in distraction forces.
CONCLUSION: The data suggest that distraction forces are not the primary factor in the mechanical stability of meniscal repair. It must therefore be assumed that other factors such as shear forces are of greater significance. CLINICAL RELEVANCE: The results may help to validate the biomechanical properties of different meniscal repair techniques.

Entities:  

Mesh:

Year:  2006        PMID: 16885513     DOI: 10.1177/0363546506290667

Source DB:  PubMed          Journal:  Am J Sports Med        ISSN: 0363-5465            Impact factor:   6.202


  11 in total

Review 1.  All-inside meniscal repair using the FasT-Fix meniscal repair system: is still needed to avoid weight bearing? A systematic review.

Authors:  Alberto Vascellari; Enrico Rebuzzi; Stefano Schiavetti; Nicolò Coletti
Journal:  Musculoskelet Surg       Date:  2012-07-07

2.  Tensile forces on sutures in the human lateral knee meniscus.

Authors:  Christian Staerke; Olaf Brettschneider; Karl-Heinz Gröbel; Roland Becker
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2009-07-24       Impact factor: 4.342

3.  What is the best way to fix a polyurethane meniscal scaffold? A biomechanical evaluation of different fixation modes.

Authors:  Francois Hardeman; Kristoff Corten; Michiel Mylle; Bert Van Herck; René Verdonk; Peter Verdonk; Johan Bellemans
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-04-12       Impact factor: 4.342

Review 4.  Meta-analysis on biomechanical properties of meniscus repairs: are devices better than sutures?

Authors:  Daniel M Buckland; Patrick Sadoghi; Matthias D Wimmer; Patrick Vavken; Geert I Pagenstert; Victor Valderrabano; Claudio Rosso
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-05-20       Impact factor: 4.342

5.  Contact mechanics after mattress suture repair of medial meniscus vertical longitudinal tear: an in vitro study.

Authors:  Zhong Chen; Haozhi Zhang; Huan Luo; Rui Yang; Zhengzheng Zhang; Chuan Jiang; Jingyi Hou; Yunfeng Zhou; Yue Xu; Bin Song; Weiping Li
Journal:  Arch Orthop Trauma Surg       Date:  2020-04-18       Impact factor: 3.067

6.  Bonding and fusion of meniscus fibrocartilage using a novel chondroitin sulfate bone marrow tissue adhesive.

Authors:  Jacob A Simson; Iossif A Strehin; Brian W Allen; Jennifer H Elisseeff
Journal:  Tissue Eng Part A       Date:  2013-06-12       Impact factor: 3.845

7.  Development of a fast curing tissue adhesive for meniscus tear repair.

Authors:  Agnieszka Izabela Bochyńska; Gerjon Hannink; Dennis Janssen; Pieter Buma; Dirk W Grijpma
Journal:  J Mater Sci Mater Med       Date:  2016-11-19       Impact factor: 3.896

8.  Increased Construct Stiffness With Meniscal Repair Sutures and Devices Increases the Risk of Cheese-Wiring During Biomechanical Load-to-Failure Testing.

Authors:  Sebastian Müller; Tanja Schwenk; Michael de Wild; Dimitris Dimitriou; Claudio Rosso
Journal:  Orthop J Sports Med       Date:  2021-06-15

Review 9.  Weightbearing Versus Nonweightbearing After Meniscus Repair.

Authors:  Kelly L VanderHave; Crystal Perkins; Michael Le
Journal:  Sports Health       Date:  2015-03-10       Impact factor: 3.843

Review 10.  Tissue adhesives for meniscus tear repair: an overview of current advances and prospects for future clinical solutions.

Authors:  A I Bochyńska; G Hannink; D W Grijpma; P Buma
Journal:  J Mater Sci Mater Med       Date:  2016-03-12       Impact factor: 3.896

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.