| Literature DB >> 16883547 |
Qing Li1, Li-Xin Sun, Liang Xu, Ying Jia, Zhi-Wei Wang, Zhen-Duo Shen, Kai-Shun Bi.
Abstract
A high-performance liquid chromatographic (HPLC) method was developed for the first time to simultaneously quantify syringin and chlorogenic acid in rat plasma using wavelength-transfer technology. The analysis was performed on a Diamonsil C(18) column (200 x 4.6 mm i.d., 5 microm particle size) with isocratic mobile phase consisting of acetonitrile-0.05% phosphoric acid (12:88, v/v). The linear ranges were 0.20-10 and 0.25-30 microg/mL, respectively. The lower limits of quantification were 0.20 and 0.25 microg/mL, respectively. The method was shown to be reproducible and reliable with intraday precision below 8.5 and 6.1%, interday precision below 7.1 and 5.5%, accuracy within +/-7.1 and +/-8.6%, and mean extraction recovery excess of 92.1 and 80.9%, respectively, which were all calculated from the blank plasma sample spiked with syringin and chlorogenic acid at three concentrations of 0.20, 1.0 and 6.0 microg/mL for syringin and 0.25, 2.0 and 20 microg/mL for chlorogenic acid. This method was validated for specificity, accuracy and precision and was successfully applied to the pharmacokinetic study of syringin and chlorogenic acid in rat plasma after intravenous administration of Aidi lyophilizer. Copyright (c) 2006 John Wiley & Sons, Ltd.Entities:
Mesh:
Substances:
Year: 2006 PMID: 16883547 DOI: 10.1002/bmc.698
Source DB: PubMed Journal: Biomed Chromatogr ISSN: 0269-3879 Impact factor: 1.902