Literature DB >> 16883121

Comparison between two on-line reversed line position hemodialysis vascular access flow measurement techniques: saline dilution and thermodilution.

Edwin Wijnen1, Stig Essers, Ger van Meijel, Jeroen P Kooman, Jan Tordoir, Karel M L Leunissen, Frank M van der Sande.   

Abstract

Periodical access flow measurements can predict the development and presence of vascular access flow-limiting stenosis and subsequent thrombosis. Access flow measurement has become a standard in vascular access care. Different techniques to measure access flow are available. The aim of this study was to compare an integrated access flow measurement device, based on thermodilution (Blood Temperature Monitor, BTM, Fresenius Medical Care, Bad Homburg, Germany), with the gold standard, the HD01 (Transonic Systems Inc., Ithaca, NY), whose technique is based on saline dilution. In 40 patients with end-stage renal disease, 40 vascular accesses were studied to determine the correlation between access flow measurements by both techniques. Reproducibility of access flow measurements by both techniques was assessed in 20 patients on a weekly interval.A total of 40 measurement series were performed. Average access flow measured with the saline technique and the thermodilution technique was 1053 (+/-495) ml/min and 1034 (+/-527) ml/min, respectively (p = ns) (n = 40). Correlation between access flow measurements by both techniques expressed in R was 0.79 (r = 0.89). Reproducibility of saline and thermodilution subsequent measurements with a weekly interval, expressed in relative difference (Delta xrel) was 13 (+/-11)% and 24 (+/-14)%, respectively (p < 0.01) (n = 20).BTM access flow measurements correlated well with the HD01 access flow measurements. However, the better reproducibility of HD01 and shorter measurement time compared with BTM access flow measurements should be considered when implementing access flow measurement to prevent vascular access failure.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16883121     DOI: 10.1097/01.mat.0000227680.67901.01

Source DB:  PubMed          Journal:  ASAIO J        ISSN: 1058-2916            Impact factor:   2.872


  3 in total

1.  Surveillance of hemodialysis vascular access.

Authors:  William L Whittier
Journal:  Semin Intervent Radiol       Date:  2009-06       Impact factor: 1.513

2.  Stent placement versus angioplasty improves patency of arteriovenous grafts and blood flow of arteriovenous fistulae.

Authors:  Micah R Chan; Surmeet Bedi; Robert J Sanchez; Henry N Young; Yolanda T Becker; Paul S Kellerman; Alexander S Yevzlin
Journal:  Clin J Am Soc Nephrol       Date:  2008-02-06       Impact factor: 8.237

3.  Effect of online haemodialysis vascular access flow evaluation and pre-emptive intervention on the frequency of access thrombosis.

Authors:  Edwin Wijnen; Frank M van der Sande; Jan H M Tordoir; Jeroen P Kooman; Karel M L Leunissen
Journal:  NDT Plus       Date:  2008-08-22
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.