Dialyzer clearances and mass transfer-area coefficients for small solutes at low dialysate flow rates.

John K Leypoldt1, Craig D Kamerath, Janice F Gilson, Goetz Friederichs.   

Abstract

New daily hemodialysis therapies operate at low dialysate flow rates to minimize dialysate volume requirements; however, the dependence of dialyzer clearances and mass transfer-area coefficients for small solutes on dialysate flow rate under these conditions have not been studied extensively. We evaluated in vitro dialyzer clearances for urea and creatinine at dialysate flow rates of 40, 80, 120, 160, and 200 ml/min and ultrafiltration flow rates of 0, 1, and 2 l/h, using a dialyzer containing PUREMA membranes (NxStage Medical, Lawrence, MA). Clearances were measured directly across the dialyzer by perfusing bovine blood with added urea and creatinine single pass through the dialyzer at a nominal blood flow rate of 400 ml/min. Limited, additional studies were performed with the use of dialyzers containing PUREMA membranes at a blood flow rate of 200 ml/min and also with the use of other dialyzers containing polysulfone membranes (Optiflux 160NR, FMC-NA, Ogden, UT) and dialyzers containing Synphan membranes (NxStage Medical). For dialyzers containing PUREMA membranes, urea and creatinine clearances increased (p < 0.001) with increasing dialysate and ultrafiltration flow rates but were not different at blood flow rates of 200 and 400 ml/min. Dialysate saturation, defined as dialysate outlet concentration divided by blood water inlet concentration, for urea and creatinine was independent of blood and ultrafiltration flow rate but varied inversely (p < 0.001) with dialysate flow rate. Mass transfer-area coefficients for urea and creatinine were independent of blood and ultrafiltration flow rate but decreased (p < 0.001) with decreasing dialysate flow rate. Calculated mass transfer-area coefficients at low dialysate flow rates for all dialyzers tested were substantially lower than those reported by the manufacturers under conventional conditions. We conclude that dialyzers require specific characterization under relevant conditions if they are used in novel daily hemodialysis therapies at low dialysate flow rate.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16883120     DOI: 10.1097/01.mat.0000227687.88929.08

Source DB:  PubMed          Journal:  ASAIO J        ISSN: 1058-2916            Impact factor:   2.872


  6 in total

1.  Creatinine generation is reduced in patients requiring continuous venovenous hemodialysis and independently predicts mortality.

Authors:  Francis P Wilson; Jessica M Sheehan; Laura H Mariani; Jeffrey S Berns
Journal:  Nephrol Dial Transplant       Date:  2012-01-23       Impact factor: 5.992

2.  Technical characterization of dialysis fluid flow and mass transfer rate in dialyzers with various filtration coefficients using dimensionless correlation equation.

Authors:  Makoto Fukuda; Kengo Yoshimura; Koki Namekawa; Kiyotaka Sakai
Journal:  J Artif Organs       Date:  2017-01-13       Impact factor: 1.731

Review 3.  How To Prescribe And Troubleshoot Continuous Renal Replacement Therapy: A Case-Based Review.

Authors:  Javier A Neyra; Lenar Yessayan; Melissa L Thompson Bastin; Keith M Wille; Ashita J Tolwani
Journal:  Kidney360       Date:  2020-12-14

4.  Novel Use of Premixed Dialysate Bags during Water Supply Interruption in Acute Hospital Setting.

Authors:  Orly F Kohn; Miguel Plascencia; Yolanda Taylor; Jay L Koyner
Journal:  Kidney360       Date:  2020-12-09

Review 5.  Eco-dialysis: fashion or necessity.

Authors:  Monika Wieliczko; Jacek Zawierucha; Adrian Covic; Tomasz Prystacki; Wojciech Marcinkowski; Jolanta Małyszko
Journal:  Int Urol Nephrol       Date:  2020-02-01       Impact factor: 2.370

6.  Covalent Organic Framework Based on Azacalix[4]arene for the Efficient Capture of Dialysis Waste Products.

Authors:  Tina Skorjanc; Dinesh Shetty; Felipe Gándara; Simon Pascal; Nawavi Naleem; Salma Abubakar; Liaqat Ali; Abdul Khayum Mohammed; Jesus Raya; Serdal Kirmizialtin; Olivier Siri; Ali Trabolsi
Journal:  ACS Appl Mater Interfaces       Date:  2022-08-22       Impact factor: 10.383

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.