Literature DB >> 16882219

Performance evaluation of the Scent Transfer Unit (STU-100) for organic compound collection and release.

Brian A Eckenrode1, Scott A Ramsey, Rex A Stockham, Gary J Van Berkel, Keiji G Asano, Dennis A Wolf.   

Abstract

The Scent Transfer Unit (STU-100) is a portable vacuum that uses airflow through a sterile gauze pad to capture a volatiles profile over evidentiary items for subsequent canine presentation to assist law enforcement personnel. This device was evaluated to determine its ability to trap and release organic compounds at ambient temperature under controlled laboratory conditions. Gas chromatography-mass spectrometry (GC-MS) analyses using a five-component volatiles mixture in methanol injected directly into a capture pad indicated that compound release could be detected initially and 3 days after the time of collection. Additionally, 15 compounds of a 39-component toxic organic gaseous mixture (10-1000 parts per billion by volume [p.p.b.(v)]) were trapped, released, and detected in the headspace of a volatiles capture pad after being exposed to this mixture using the STU-100 with analysis via GC-MS. Component release efficiencies at ambient temperature varied with the analyte; however, typical values of c. 10% were obtained. Desorption at elevated temperatures of reported human odor/scent chemicals and colognes trapped by the STU-100 pads was measured and indicated that the STU-100 has a significant trapping efficiency at ambient temperature. Multivariate statistical analysis of subsequent mass spectral patterns was also performed.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16882219     DOI: 10.1111/j.1556-4029.2006.00178.x

Source DB:  PubMed          Journal:  J Forensic Sci        ISSN: 0022-1198            Impact factor:   1.832


  2 in total

Review 1.  A Review of the Types of Training Aids Used for Canine Detection Training.

Authors:  Alison Simon; Lucia Lazarowski; Melissa Singletary; Jason Barrow; Kelly Van Arsdale; Thomas Angle; Paul Waggoner; Kathleen Giles
Journal:  Front Vet Sci       Date:  2020-06-05

2.  Application of a Microfluidic Gas-to-Liquid Interface for Extraction of Target Amphetamines and Precursors from Air Samples.

Authors:  Michael Collins; Murat Gel; Chris Lennard; Val Spikmans; Shari Forbes; Alisha Anderson
Journal:  Micromachines (Basel)       Date:  2020-03-17       Impact factor: 2.891

  2 in total