Literature DB >> 16880844

Real-time quadrature projection complex conjugate resolved Fourier domain optical coherence tomography.

Marinko V Sarunic1, Brian E Applegate, Joseph A Izatt.   

Abstract

We present a novel algorithm for full-range imaging by suppression of the complex conjugate artifact in phase-shifting Fourier domain optical coherence tomography. This technique utilizes the projection of multiple phase-shifted interferograms onto an orthogonal basis set to reconstruct the complex interferogram. Full-range imaging with >30 dB suppression of the symmetric artifact is demonstrated using a 3 x 3 fiber coupler swept source OCT system, providing a depth range of 6.6mm with -8 dB roll-off in sensitivity at the depth boundaries relative to DC. Real-time display of full-range images of the anterior segment of the human eye acquired in vivo at a line rate of 6.67 kHz are presented.

Entities:  

Mesh:

Year:  2006        PMID: 16880844     DOI: 10.1364/ol.31.002426

Source DB:  PubMed          Journal:  Opt Lett        ISSN: 0146-9592            Impact factor:   3.776


  10 in total

1.  Comparison of phase-shifting techniques for in vivo full-range, high-speed Fourier-domain optical coherence tomography.

Authors:  Dae Yu Kim; John S Werner; Robert J Zawadzki
Journal:  J Biomed Opt       Date:  2010 Sep-Oct       Impact factor: 3.170

2.  Detailed visualization of the anterior segment using fourier-domain optical coherence tomography.

Authors:  Sanjay Asrani; Marinko Sarunic; Cecilia Santiago; Joseph Izatt
Journal:  Arch Ophthalmol       Date:  2008-06

3.  Imaging the ocular anterior segment with real-time, full-range Fourier-domain optical coherence tomography.

Authors:  Marinko V Sarunic; Sanjay Asrani; Joseph A Izatt
Journal:  Arch Ophthalmol       Date:  2008-04

4.  Full-depth spectral domain optical coherence tomography technology insensitive to phase disturbance.

Authors:  Luying Yi; Liqun Sun; Xianshun Ming; Mingli Zou
Journal:  Biomed Opt Express       Date:  2018-10-01       Impact factor: 3.732

5.  Numerical calibration method for a multiple spectrometer-based OCT system.

Authors:  Yusi Miao; Jun Song; Destiny Hsu; Ringo Ng; Yifan Jian; Marinko V Sarunic; Myeong Jin Ju
Journal:  Biomed Opt Express       Date:  2022-02-24       Impact factor: 3.732

Review 6.  Fourier-domain optical coherence tomography: recent advances toward clinical utility.

Authors:  Brett E Bouma; Seok-Hyun Yun; Benjamin J Vakoc; Melissa J Suter; Guillermo J Tearney
Journal:  Curr Opin Biotechnol       Date:  2009-03-04       Impact factor: 9.740

7.  Ultrahigh-resolution spectral domain optical coherence tomography imaging of the lamina cribrosa.

Authors:  Larry Kagemann; Hiroshi Ishikawa; Gadi Wollstein; Peter M Brennen; Kelly A Townsend; Michelle L Gabriele; Joel S Schuman
Journal:  Ophthalmic Surg Lasers Imaging       Date:  2008 Jul-Aug

8.  Complete complex conjugate resolved heterodyne swept-source optical coherence tomography using a dispersive optical delay line.

Authors:  Al-Hafeez Dhalla; Joseph A Izatt
Journal:  Biomed Opt Express       Date:  2011-04-15       Impact factor: 3.732

9.  Complex conjugate resolved heterodyne swept source optical coherence tomography using coherence revival.

Authors:  Al-Hafeez Dhalla; Derek Nankivil; Joseph A Izatt
Journal:  Biomed Opt Express       Date:  2012-02-24       Impact factor: 3.732

10.  Double Interferometer Design for Independent Wavefront Manipulation in Spectral Domain Optical Coherence Tomography.

Authors:  Jonas Kanngiesser; Maik Rahlves; Bernhard Roth
Journal:  Sci Rep       Date:  2019-10-10       Impact factor: 4.379

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.