Literature DB >> 16880158

Semi-automated segmentation and visualisation of outer bone cortex from medical images.

F Gelaude1, J Vander Sloten, B Lauwers.   

Abstract

Good segmentation of the outer bone cortex from medical images is a prerequisite for applications in the field of finite element analysis, surgical planning environments and personalised, case dependent, bone reconstruction. However, current segmentation procedures are often unsatisfactory. This study presents an automated filter procedure to generate a set of adapted contours from which a surface mesh can be deduced directly. The degree of interaction is user determined. The bone contours are extracted from the patients CT data by quick grey value segmentation. An extended filter procedure then only retains contour information representing the outer cortex as more specific internal loops and shape irregularities are removed, tailoring the image for the above-mentioned applications. The developed medical image based design methodology to convert contour sets of multiple bone types, from tibia tumour to neurocranium, is reported and discussed.

Entities:  

Mesh:

Year:  2006        PMID: 16880158     DOI: 10.1080/10255840600604474

Source DB:  PubMed          Journal:  Comput Methods Biomech Biomed Engin        ISSN: 1025-5842            Impact factor:   1.763


  4 in total

1.  An optimized process flow for rapid segmentation of cortical bones of the craniofacial skeleton using the level-set method.

Authors:  T D Szwedowski; J Fialkov; A Pakdel; C M Whyne
Journal:  Dentomaxillofac Radiol       Date:  2013-02-18       Impact factor: 2.419

2.  Semi-automated phalanx bone segmentation using the expectation maximization algorithm.

Authors:  Austin J Ramme; Nicole DeVries; Nicole A Kallemyn; Vincent A Magnotta; Nicole M Grosland
Journal:  J Digit Imaging       Date:  2008-09-03       Impact factor: 4.056

3.  Automated cortical bone segmentation for multirow-detector CT imaging with validation and application to human studies.

Authors:  Cheng Li; Dakai Jin; Cheng Chen; Elena M Letuchy; Kathleen F Janz; Trudy L Burns; James C Torner; Steven M Levy; Punam K Saha
Journal:  Med Phys       Date:  2015-08       Impact factor: 4.071

4.  Interlaboratory comparison of femur surface reconstruction from CT data compared to reference optical 3D scan.

Authors:  Ehsan Soodmand; Daniel Kluess; Patrick A Varady; Robert Cichon; Michael Schwarze; Dominic Gehweiler; Frank Niemeyer; Dieter Pahr; Matthias Woiczinski
Journal:  Biomed Eng Online       Date:  2018-03-02       Impact factor: 2.819

  4 in total