A prospective study comparing different iodine concentrations for triphasic multidetector row CT of the upper abdomen.

Joern J W Sandstede1, Alexander Werner, Christine Kaupert, Anne Roth, Manfred Jenett, Cornelia Harz, Dietbert Hahn.   

Abstract

OBJECTIVES: To investigate the effect of different iodine concentrations at either constant injection or iodine administration rates but constant total iodine load on contrast enhancement of liver, pancreas and spleen by multidetector row CT.
MATERIALS AND METHODS: One hundred and twenty consecutive patients (70+/-6 years) underwent triphasic liver CT at a four-channel multidetector-row CT using the non-ionic contrast medium iopromide. Patients were divided into six equal groups-I: 150 ml, 240 mg/ml at 4 ml/s; II: 120 ml, 300 mg/ml at 4 ml/s; III: 97.3 ml, 370 mg/ml at 4 ml/s; IV: 150 ml, 240 mg/ml at 5 ml/s; V: 120 ml, 300 mg/ml, 60 ml at 6 ml/s, 60 ml at 3 ml/s; VI: 97.3 ml, 370 mg/ml at 3.3 ml/s. ROIs were measured in the liver, the pancreas, and the spleen in unenhanced, arterial, portal venous, and equilibrium phase.
RESULTS: At a constant injection rate of 4 ml/s, pancreatic enhancement over baseline only in the arterial phase was significantly higher at 370 mg/ml (58+/-15 HU versus 59+/-18 HU versus 74+/-20 HU for groups I-III, respectively (p<0.02)). Comparison of different iodine concentrations at constant iodine administration rate (groups II, IV and VI) and of all six protocols revealed no significant differences at either phase.
CONCLUSIONS: At a constant iodine load and constant injection rates, the high-iodinated contrast agent iopromide at 370 mg/ml improves pancreatic enhancement in the arterial phase. At constant iodine load and constant iodine administration rates, there is no significant effect of different iodine concentrations.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16879942     DOI: 10.1016/j.ejrad.2006.05.012

Source DB:  PubMed          Journal:  Eur J Radiol        ISSN: 0720-048X            Impact factor:   3.528


  7 in total

1.  Contrast enhancement in multidetector-row computed tomography (MDCT) of the abdomen: intraindividual comparison of contrast media containing 300 mg versus 370 mg iodine per ml.

Authors:  F F Behrendt; A H Mahnken; S Keil; M Das; C Hohl; D Bauer; P Seidensticker; E Jost; J E Wildberger; R W Günther; G Mühlenbruch
Journal:  Eur Radiol       Date:  2008-01-29       Impact factor: 5.315

2.  MDCT angiography of the pulmonary arteries: intravascular contrast enhancement does not depend on iodine concentration when injecting equal amounts of iodine at standardized iodine delivery rates.

Authors:  S Keil; C Plumhans; F F Behrendt; M Das; S Stanzel; G Mühlenbruch; P Seidensticker; C Knackstedt; A H Mahnken; R W Günther; J E Wildberger
Journal:  Eur Radiol       Date:  2008-04-08       Impact factor: 5.315

3.  A comparison of the use of contrast media with different iodine concentrations for multidetector CT of the kidney.

Authors:  Seung Chai Jung; Seung Hyup Kim; Jeong Yeon Cho
Journal:  Korean J Radiol       Date:  2011-09-27       Impact factor: 3.500

4.  Which Iodine concentration in chest CT?--a prospective study in 300 patients.

Authors:  Georg Mühlenbruch; Florian F Behrendt; Mohammed A Eddahabi; Christian Knackstedt; Sven Stanzel; Marco Das; Peter Seidensticker; Rolf W Günther; Joachim E Wildberger; Andreas H Mahnken
Journal:  Eur Radiol       Date:  2008-07-24       Impact factor: 5.315

5.  Automatic bolus tracking versus fixed time-delay technique in biphasic multidetector computed tomography of the abdomen.

Authors:  Atoosa Adibi; Ali Shahbazi
Journal:  Iran J Radiol       Date:  2014-01-30       Impact factor: 0.212

6.  An Individually Optimized Protocol of Contrast Medium Injection in Enhanced CT Scan for Liver Imaging.

Authors:  Shi-Ting Feng; Hongzhang Zhu; Zhenpeng Peng; Li Huang; Zhi Dong; Ling Xu; Kun Huang; Xufeng Yang; Zhi Lin; Zi-Ping Li
Journal:  Contrast Media Mol Imaging       Date:  2017-07-10       Impact factor: 3.161

7.  Comparison of enhancement and image quality: different iodine concentrations for liver on 128-slice multidetector computed tomography in the same chronic liver disease patients.

Authors:  Byoung Goo Jo; Yun Gyu Song; Sang Goon Shim; Young Wook Kim
Journal:  Korean J Intern Med       Date:  2015-12-23       Impact factor: 2.884

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.