Literature DB >> 16879156

Comparison of the performance of microtube column systems and solid-phase systems and the tube low-ionic-strength solution additive indirect antiglobulin test in the detection of red cell alloantibodies.

V Weisbach1, T Kohnhäuser, R Zimmermann, J Ringwald, E Strasser, J Zingsem, R Eckstein.   

Abstract

To compare the performance of seven currently available test systems in the detection of erythrocyte alloantibodies (ab), we tested in parallel 446 sera samples containing red cell ab [368 sera samples with ab that are assumed to be clinically significant (cs-ab) and 78 sera samples with ab that are assumed to be of minor clinical significance (ms-ab)] using the tube spin low-ionic-strength solution (addition method) indirect antiglobulin test (tube LISS-IAT), three microtube column agglutination techniques (DiaMed-ID, Ortho BioVue and Bio-Rad Scangel), one affinity adherence test system (CLB/Mast CellBind Screen) and two solid-phase tests [Biotest Solidscreen II and Immucor Capture-R Ready-Screen (4)]. To address the specificity of the three test systems under routine conditions, results of 4566 patient samples obtained using the tube LISS-IAT, results of 5205 patient samples obtained using the Scangel and results of 3560 samples obtained using the Capture-R were evaluated. The DiaMed-ID detected 344 cs-ab and 43 ms-ab, BioVue 333 cs-ab and 48 ms-ab, Scangel 348 cs-ab and 62 ms-ab, CellBind Screen 346 cs-ab and 47 ms-ab, Solidscreen 330 cs-ab and 38 ms-ab, Capture-R 358 cs-ab and 45 ms-ab and LISS-IAT 159 cs-ab and 12 ms-ab. In routine practice, erythrocyte cs-ab could be identified in 61 (67.8%) of 90 reactive sera (specificity: 98.6%) in the tube LISS-IAT, in 169 (58.7%) of 288 (94.4%) in Bio-Rad Scangel and in 101 (51.0%) of 198 reactive sera (94.3%) in Capture-R. We conclude that the sensitivity of the microcolumn, affinity adherence and solid-phase test systems in the detection of cs-ab was similar and was markedly superior to that of the conventional tube LISS-IAT. All high-sensitive test systems produced higher rates of false positives and ms-ab compared to the tube test. An individual cost-benefit analysis, considering the recent knowledge about the clinical significance of weak-reactive cs-ab, should be performed in every institution to decide whether and if so which high-sensitive screening system should be applied.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16879156     DOI: 10.1111/j.1365-3148.2006.00674.x

Source DB:  PubMed          Journal:  Transfus Med        ISSN: 0958-7578            Impact factor:   2.019


  7 in total

1.  A rewarding fresh look at routine blood group data.

Authors:  Willy A Flegel
Journal:  Blood Transfus       Date:  2008-10       Impact factor: 3.443

2.  Increased detection of clinically significant antibodies and decreased incidence of delayed haemolytic transfusion reaction with the indirect antiglobulin test potentiated by polyethylene glycol compared to albumin: a Japanese study.

Authors:  Miho Okutsu; Hitoshi Ohto; Hiroyasu Yasuda; Kinuyo Kawabata; Satoshi Ono; Shunnichi Saito; Akiko Sugawara; Masami Kikuchi; Saori Miura; Youko Ishii; Kazuya Watanabe; Yuriko Tohyama; Kenneth E Nollet
Journal:  Blood Transfus       Date:  2010-11-26       Impact factor: 3.443

3.  Evaluation of the New Lateral Flow Card MDmulticard® Basic Extended Phenotype in Routine Clinical Practice.

Authors:  Beate Mayer; Julia Müller; María-José Candela-García; Annie-Claude Manteau; Christof Weinstock; Axel Pruß
Journal:  Transfus Med Hemother       Date:  2018-03-09       Impact factor: 3.747

4.  Comparison of micro column technology with conventional tube methods for antibody detection.

Authors:  Sachin Garg; Nishant Saini; Ravneet Kaur Bedi; Sabita Basu
Journal:  J Lab Physicians       Date:  2017 Apr-Jun

5.  A comparison of three column agglutination tests for red blood cell alloantibody identification.

Authors:  Siska Blomme; Emilie De Maertelaere; Eline Verhoye
Journal:  BMC Res Notes       Date:  2020-03-04

6.  Automation in immunohematology.

Authors:  Meenu Bajpai; Ravneet Kaur; Ekta Gupta
Journal:  Asian J Transfus Sci       Date:  2012-07

7.  Comparison of two column agglutination tests for red blood cell antibody testing.

Authors:  Jonas Sawierucha; Marion Posset; Viola Hähnel; Christian L Johnson; James A Hutchinson; Norbert Ahrens
Journal:  PLoS One       Date:  2018-12-31       Impact factor: 3.240

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.