Literature DB >> 16878632

Saphenous vein graft flow during left ventricular assistance with an axial-flow pump.

Matthew D Forrester1, Timothy J Myers, Igor D Gregoric, O H Frazier.   

Abstract

The effects of continuous-flow support on bypass graft flow have not been quantified clinically. Continuous-flow left ventricular assist devices unload the left ventricle throughout the cardiac cycle, which narrows pulse pressure and converts passive left ventricular filling during diastole to active flow throughout the cardiac cycle. We report the case of a 63-year-old man with severe congestive heart failure who underwent coronary artery bypass grafting and was supported with an axial-flow pump. In this patient, saphenous vein graft flow during left ventricular assistance provided adequate coronary perfusion.

Entities:  

Mesh:

Year:  2006        PMID: 16878632      PMCID: PMC1524688     

Source DB:  PubMed          Journal:  Tex Heart Inst J        ISSN: 0730-2347


  5 in total

1.  Initial experience with the Jarvik 2000 left ventricular assist system as a bridge to transplantation: report of 4 cases.

Authors:  O H. Frazier; I D. Gregoric; R M. Delgado; T J. Myers; B Radovancevic; T Khan; K Miller; J K. Ho; R K. Jarvik
Journal:  J Heart Lung Transplant       Date:  2001-02       Impact factor: 10.247

2.  Mechanical assistance of the left ventricle: acute effect on cardiac performance and coronary flow of different perfusion patterns.

Authors:  F Bellotto; R G Johnson; J Watanabe; M J Levine; A Franklin; R M Weintraub
Journal:  J Thorac Cardiovasc Surg       Date:  1992-09       Impact factor: 5.209

3.  Experimental subendocardial ischemia in dogs with normal coronary arteries.

Authors:  G D Buckberg; D E Fixler; J P Archie; J I Hoffman
Journal:  Circ Res       Date:  1972-01       Impact factor: 17.367

4.  Effect of the hemopump left ventricular assist device on regional myocardial perfusion and function. Reduction of ischemia during coronary occlusion.

Authors:  M E Merhige; R W Smalling; D Cassidy; R Barrett; G Wise; J Short; R K Wampler
Journal:  Circulation       Date:  1989-11       Impact factor: 29.690

5.  Improved regional myocardial blood flow, left ventricular unloading, and infarct salvage using an axial-flow, transvalvular left ventricular assist device. A comparison with intra-aortic balloon counterpulsation and reperfusion alone in a canine infarction model.

Authors:  R W Smalling; D B Cassidy; R Barrett; B Lachterman; P Felli; J Amirian
Journal:  Circulation       Date:  1992-03       Impact factor: 29.690

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.