Literature DB >> 16878313

MRT letter: high speed scanning has the potential to increase fluorescence yield and to reduce photobleaching.

Rolf T Borlinghaus1.   

Abstract

True confocal microscopy requires point-shaped illumination and detection. To generate an image, a diffraction limited spot is moved over the sample. Single spot scanning has suffered in the past from low image rates; a solution is the employment of very fast scanning devices (resonant scanners) for x-movement. In the process of introducing resonant scanning devices, it was found that both signal yield is improved and bleaching is decreased-in contrary to the assumed performance. This article will show by a simple and well understood model a straightforward explanation for the potential increase of signal yield and decrease in photobleaching. The time that is ruling the dose-rate effects is the effective time; a fluorochrome is illuminated. This time depends on the diameter of the spot that is moved over the sample and the speed at which the spot moves. In essence, the scan process causes a pulsed illumination of the fluorochromes. Various schemes of pulsed illumination are simulated with a fluorescence model. The model includes a dark state, where fluorochromes will exit the fluorescence process and slowly decay back into the ground state. Upon splitting a single dose into two pulses separated by a dark time-reflecting an increased scan speed-the amount of fluorescence emission is increased and bleaching is reduced. These results show a potential increase of fluorescence and a lower photobleaching upon higher scan speed. As illumination during the bleach-phase in a FRAP-experiment is similar to a light pulse, the findings also suggest to critically consider the very beginning of fluorescence recovery in terms of triplet relaxation process that potentially could falsify the measurements. (c) 2006 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2006        PMID: 16878313     DOI: 10.1002/jemt.20363

Source DB:  PubMed          Journal:  Microsc Res Tech        ISSN: 1059-910X            Impact factor:   2.769


  16 in total

1.  Beam scanning for rapid coherent Raman hyperspectral imaging.

Authors:  Ian Seungwan Ryu; Charles H Camp; Ying Jin; Marcus T Cicerone; Young Jong Lee
Journal:  Opt Lett       Date:  2015-12-15       Impact factor: 3.776

2.  Analysis of protein mobilities and interactions in living cells by multifocal fluorescence fluctuation microscopy.

Authors:  Gerrit Heuvelman; Fabian Erdel; Malte Wachsmuth; Karsten Rippe
Journal:  Eur Biophys J       Date:  2009-06-19       Impact factor: 1.733

3.  Live-cell imaging.

Authors:  Richard Cole
Journal:  Cell Adh Migr       Date:  2014-10-31       Impact factor: 3.405

4.  Any Way You Slice It-A Comparison of Confocal Microscopy Techniques.

Authors:  James Jonkman; Claire M Brown
Journal:  J Biomol Tech       Date:  2015-07

5.  Volumetric Lissajous confocal microscopy with tunable spatiotemporal resolution.

Authors:  Takahiro Deguchi; Paolo Bianchini; Gemma Palazzolo; Michele Oneto; Alberto Diaspro; Martí Duocastella
Journal:  Biomed Opt Express       Date:  2020-10-13       Impact factor: 3.732

6.  Two-photon calcium imaging in mice navigating a virtual reality environment.

Authors:  Marcus Leinweber; Pawel Zmarz; Peter Buchmann; Paul Argast; Mark Hübener; Tobias Bonhoeffer; Georg B Keller
Journal:  J Vis Exp       Date:  2014-02-20       Impact factor: 1.355

7.  An efficient method for quantitative, single-cell analysis of chromatin modification and nuclear architecture in whole-mount ovules in Arabidopsis.

Authors:  Wenjing She; Daniel Grimanelli; Célia Baroux
Journal:  J Vis Exp       Date:  2014-06-19       Impact factor: 1.355

Review 8.  Ratiometric optical nanoprobes enable accurate molecular detection and imaging.

Authors:  Xiaolin Huang; Jibin Song; Bryant C Yung; Xiaohua Huang; Yonghua Xiong; Xiaoyuan Chen
Journal:  Chem Soc Rev       Date:  2018-04-23       Impact factor: 54.564

9.  Long-term monitoring of live cell proliferation in presence of PVP-Hypericin: a new strategy using ms pulses of LED and the fluorescent dye CFSE.

Authors:  Rozhin Penjweini; Hans G Loew; Michael R Hamblin; Karl W Kratky
Journal:  J Microsc       Date:  2011-10-04       Impact factor: 1.758

10.  Preparation of developing and adult Drosophila brains and retinae for live imaging.

Authors:  W Ryan Williamson; P Robin Hiesinger
Journal:  J Vis Exp       Date:  2010-03-15       Impact factor: 1.355

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.