Literature DB >> 16877956

The optimal scheme of self blood pressure measurement as determined from ambulatory blood pressure recordings.

Willem J Verberk1, Abraham A Kroon, Alfons G H Kessels, Jacques W M Lenders, Theo Thien, Gert A van Montfrans, Andries J Smit, Peter W de Leeuw.   

Abstract

OBJECTIVE: To determine how many self-measurements of blood pressure (BP) should be taken at home in order to obtain a reliable estimate of a patient's BP.
DESIGN: Participants performed self blood pressure measurement (SBPM) for 7 days (triplicate morning and evening readings). In all of them, office blood pressure (three consecutive readings) and 24-h ambulatory blood pressure were obtained as well. Average SBPM values, obtained from several combinations of readings, were correlated with the results of ambulatory blood pressure measurement (ABPM). In addition, we assessed whether certain patient characteristics would influence such correlations.
SETTING: Patients were recruited at hospital or general practice. PATIENTS: A total of 216 untreated hypertensive patients.
RESULTS: The average SBPM value calculated from day 3 to day 7, omitting the first measurement of each morning and evening session, gave the best correlation with 24-h ABPM (r = 0.70). However, similar results were obtained from a SBPM value averaged from day 3 until 5 without the first measurement of each triplicate session. Overall, younger patients had significantly better correlations than older ones. Women had significantly better correlations with ABPM than men for systolic morning and daytime SBPM, whereas men had significantly better correlations for daytime and evening diastolic SBPM (P < 0.001). In addition, all correlations increased with lower systolic office blood pressure measurement (OBPM) values.
CONCLUSIONS: A minimum number of 5 days of measurement is recommended to obtain a reliable estimate of a patient's usual BP. On each day, three consecutive morning and evening measurements should be performed. For calculating the average SBPM, the first 2 days and the first measurement of each triplicate measurements should be discarded. Moreover, patient characteristics may have an impact on the number of necessary self-measurements. However, because adhering to these recommendations will make SBPM a time-consuming procedure, this type of measurement should be performed only when a decision about starting or changing antihypertensive therapy is needed or in the case of special patient groups.

Entities:  

Mesh:

Year:  2006        PMID: 16877956     DOI: 10.1097/01.hjh.0000239289.87141.b6

Source DB:  PubMed          Journal:  J Hypertens        ISSN: 0263-6352            Impact factor:   4.844


  20 in total

1.  Waiting a few extra minutes before measuring blood pressure has potentially important clinical and research ramifications.

Authors:  S B Nikolic; W P Abhayaratna; R Leano; M Stowasser; J E Sharman
Journal:  J Hum Hypertens       Date:  2013-05-30       Impact factor: 3.012

2.  Pragmatic Method Using Blood Pressure Diaries to Assess Blood Pressure Control.

Authors:  James E Sharman; Leigh Blizzard; Wojciech Kosmala; Mark R Nelson
Journal:  Ann Fam Med       Date:  2016 Jan-Feb       Impact factor: 5.166

3.  Reproducibility of masked hypertension among adults 30 years or older.

Authors:  Anthony J Viera; Feng-Chang Lin; Laura A Tuttle; Emily Olsson; Kristin Stankevitz; Susan S Girdler; J Larry Klein; Alan L Hinderliter
Journal:  Blood Press Monit       Date:  2014-08       Impact factor: 1.444

4.  Compliance with home blood pressure monitoring among middle-aged Korean Americans with hypertension.

Authors:  Jiyun Kim; Hae-Ra Han; Heejung Song; JongEun Lee; Kim B Kim; Miyong T Kim
Journal:  J Clin Hypertens (Greenwich)       Date:  2010-04       Impact factor: 3.738

Review 5.  Within-Home Blood Pressure Variability on a Single Occasion Has Clinical Significance.

Authors:  Seiichi Shibasaki; Satoshi Hoshide; Kazuomi Kario
Journal:  Pulse (Basel)       Date:  2016-05-12

6.  Impact of Clinic-Based Blood Pressure Approaches on Blood Pressure Measurement.

Authors:  Stephen P Juraschek; Anthony Ishak; Kenneth J Mukamal; Marc L Cohen; Jennifer L Beach
Journal:  Am J Hypertens       Date:  2020-01-01       Impact factor: 2.689

7.  Call to action on use and reimbursement for home blood pressure monitoring: a joint scientific statement from the American Heart Association, American Society Of Hypertension, and Preventive Cardiovascular Nurses Association.

Authors:  Thomas G Pickering; Nancy Houston Miller; Gbenga Ogedegbe; Lawrence R Krakoff; Nancy T Artinian; David Goff
Journal:  Hypertension       Date:  2008-05-22       Impact factor: 10.190

8.  What is the optimal interval between successive home blood pressure readings using an automated oscillometric device?

Authors:  Kazuo Eguchi; Sujith Kuruvilla; Gbenga Ogedegbe; William Gerin; Joseph E Schwartz; Thomas G Pickering
Journal:  J Hypertens       Date:  2009-06       Impact factor: 4.844

9.  A texting-based blood pressure surveillance intervention.

Authors:  Roula S Zahr; Chris A Anthony; Philip M Polgreen; Jacob E Simmering; Christopher J Goerdt; Angela B Hoth; Michelle L Miller; Manish Suneja; Alberto M Segre; Barry L Carter; Joseph E Cavanaugh; Linnea A Polgreen
Journal:  J Clin Hypertens (Greenwich)       Date:  2019-09-10       Impact factor: 3.738

10.  Use of home blood pressure monitoring by hypertensive patients in primary care: survey of a practice-based research network cohort.

Authors:  Anthony J Viera; Lauren W Cohen; C Madeline Mitchell; Philip D Sloane
Journal:  J Clin Hypertens (Greenwich)       Date:  2008-04       Impact factor: 3.738