Literature DB >> 16877566

Cardiac diastolic dysfunction in conscious dogs with heart failure induced by chronic coronary microembolization.

Robert M Gill1, Bonita D Jones, Angela K Corbly, Juan Wang, Julian C Braz, George E Sandusky, Jie Wang, Weiqun Shen.   

Abstract

Left ventricular (LV) diastolic dysfunction is a fundamental impairment in congestive heart failure (CHF). This study examined LV diastolic function in the canine model of CHF induced by chronic coronary embolization (CCE). Dogs were implanted with coronary catheters (both left anterior descending and circumflex arteries) for CCE and instrumented for measurement of LV pressure and dimension. Heart failure was elicited by daily intracoronary injections of microspheres (1.2 million, 90- to 120-microm diameter) for 24 +/- 4 days, resulting in significant depression of cardiac systolic function. After CCE, LV maximum negative change of pressure with time (dP/dt(min)) decreased by 25 +/- 2% (P < 0.05) and LV isovolumic relaxation constant and duration increased by 19 +/- 5% and 25 +/- 6%, respectively (both P < 0.05), indicating an impairment of LV active relaxation, which was cardiac preload independent. LV passive viscoelastic properties were evaluated from the LV end-diastolic pressure (EDP)-volume (EDV) relationship (EDP = be(alpha*EDV)) during brief inferior vena caval occlusion and acute volume loading, while the chamber stiffness coefficient (alpha) increased by 62 +/- 10% (P < 0.05) and the stiffness constant (k) increased by 66 +/- 13% after CCE. The regional myocardial diastolic stiffness in LV anterior and posterior walls was increased by 70 +/- 25% and 63 +/- 24% (both P < 0.05), respectively, after CCE, associated with marked fibrosis, increase in collagen I and III, and enhancement of plasminogen activator inhibitor-1 (PAI-1) protein expression. Thus along with depressed LV systolic function there is significant impairment of LV diastolic relaxation and increase in chamber stiffness, with development of myocardial fibrosis and activation of PAI-1, in the canine model of CHF induced by CCE.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16877566     DOI: 10.1152/ajpheart.00052.2006

Source DB:  PubMed          Journal:  Am J Physiol Heart Circ Physiol        ISSN: 0363-6135            Impact factor:   4.733


  7 in total

1.  Alteration of LV end-diastolic volume by controlling the power of the continuous-flow LVAD, so it is synchronized with cardiac beat: development of a native heart load control system (NHLCS).

Authors:  Akihide Umeki; Takashi Nishimura; Masahiko Ando; Yoshiaki Takewa; Kenji Yamazaki; Shunei Kyo; Minoru Ono; Tomonori Tsukiya; Toshihide Mizuno; Yoshiyuki Taenaka; Eisuke Tatsumi
Journal:  J Artif Organs       Date:  2011-11-12       Impact factor: 1.731

Review 2.  Diagnosis of coronary microvascular dysfunction - Present status.

Authors:  S R Mittal
Journal:  Indian Heart J       Date:  2015-11-06

3.  Establishment and characterization of an experimental model of coronary thrombotic microembolism in rats.

Authors:  Ye Gu; Yupeng Bai; Jie Wu; Liqun Hu; Bo Gao
Journal:  Am J Pathol       Date:  2010-07-22       Impact factor: 4.307

4.  Change in myocardial oxygen consumption employing continuous-flow LVAD with cardiac beat synchronizing system, in acute ischemic heart failure models.

Authors:  Akihide Umeki; Takashi Nishimura; Yoshiaki Takewa; Masahiko Ando; Mamoru Arakawa; Yuichiro Kishimoto; Tomonori Tsukiya; Toshihide Mizuno; Shunei Kyo; Minoru Ono; Yoshiyuki Taenaka; Eisuke Tatsumi
Journal:  J Artif Organs       Date:  2013-01-17       Impact factor: 1.731

5.  Development of a novel drive mode to prevent aortic insufficiency during continuous-flow LVAD support by synchronizing rotational speed with heartbeat.

Authors:  Yuichiro Kishimoto; Yoshiaki Takewa; Mamoru Arakawa; Akihide Umeki; Masahiko Ando; Takashi Nishimura; Yutaka Fujii; Toshihide Mizuno; Motonobu Nishimura; Eisuke Tatsumi
Journal:  J Artif Organs       Date:  2013-01-23       Impact factor: 1.731

Review 6.  Coronary microvascular dysfunction in the clinical setting: from mystery to reality.

Authors:  Joerg Herrmann; Juan Carlos Kaski; Amir Lerman
Journal:  Eur Heart J       Date:  2012-08-22       Impact factor: 29.983

7.  Influence of intraaortic balloon pump counterpulsation on transesophageal echocardiography derived determinants of diastolic function.

Authors:  Martina Nowak-Machen; Jan N Hilberath; Peter Rosenberger; Eckhard Schmid; Stavros G Memtsoudis; Johannes Angermair; Jayshree K Tuli; Stanton K Shernan
Journal:  PLoS One       Date:  2015-03-04       Impact factor: 3.240

  7 in total