Literature DB >> 16877071

Comparison of polypropylene and silicone Ahmed Glaucoma Valves.

Kyoko Ishida1, Peter A Netland, Vital P Costa, Lineu Shiroma, Baseer Khan, Iqbal Ike K Ahmed.   

Abstract

PURPOSE: To evaluate and compare the clinical outcomes after implantation of the silicone plate and the polypropylene plate Ahmed Glaucoma Valves.
DESIGN: Prospective, multicenter, comparative series.
METHODS: A total of 132 patients with uncontrolled glaucoma were treated with either the silicone or polypropylene Ahmed Glaucoma Valve implant. MAIN OUTCOME MEASURES: Success was defined according to 2 criteria: (1) intraocular pressure (IOP) of 6 mmHg or more or 21 mmHg or less, and (2) IOP reduction of at least 30% relative to preoperative values. Eyes requiring further glaucoma surgery, including cyclophotocoagulation, or showing loss of light perception were classified as failures.
RESULTS: Average follow-up was 12.8 months (range, 6-30 months) for the silicone plate group and 14.5 months (range, 6-30 months) for the polypropylene plate group (P = 0.063). At the last follow-up examination, the mean IOP was 13.8+/-3.9 mmHg and 17.3+/-6.5 mmHg (P<0.0001) and the mean number of antiglaucoma medications was 1.9+/-1.3 and 2.1+/-1.4 (P = 0.48) in the silicone plate and polypropylene plate groups, respectively. The life-table success rates for the silicone plate and polypropylene plate groups were 94.2% and 83.2% at 12 months and 82.4% and 56.7% at 24 months by definition 1, respectively (P = 0.035). When an IOP reduction of at least 30% was used for success criterion (definition 2), probabilities of success were 89.5% and 71.7% at 12 months and 78.3% and 68.5% at 24 months in the silicone and the polypropylene plate groups, respectively (P = 0.012). Visual outcomes were comparable between the 2 groups. However, complications including Tenon's cyst were observed more frequently in the polypropylene plate than in the silicone plate group (P<0.05).
CONCLUSIONS: The silicone Ahmed Glaucoma Valve (model FP7) showed improved IOP reduction compared with the polypropylene (model S2) implant. Differences observed in mean IOP, success rate, and complications suggest that plate material may influence clinical outcome.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16877071     DOI: 10.1016/j.ophtha.2006.04.020

Source DB:  PubMed          Journal:  Ophthalmology        ISSN: 0161-6420            Impact factor:   12.079


  38 in total

1.  Intraoperative testing of opening and closing pressure predicts risk of low intraocular pressure after Ahmed glaucoma valve implantation.

Authors:  F Bochmann; A Kipfer; J Tarantino; C Kaufmann; L Bachmann; M Thiel
Journal:  Eye (Lond)       Date:  2014-07-25       Impact factor: 3.775

2.  [Pathophysiology of fibrotic encapsulation of episcleral glaucoma drainage implants: modification for improvement of clinical results].

Authors:  L Choritz; M Wegner; R Förch; U Jonas; H Thieme
Journal:  Ophthalmologe       Date:  2013-08       Impact factor: 1.059

3.  [Clinical results of encapsulated bleb removal after Ahmed glaucoma valve implants].

Authors:  J Rosbach; L Choritz; N Pfeiffer; H Thieme
Journal:  Ophthalmologe       Date:  2013-08       Impact factor: 1.059

Review 4.  Current status of epibulbar anti-glaucoma drainage devices in glaucoma surgery.

Authors:  Hagen Thieme
Journal:  Dtsch Arztebl Int       Date:  2012-10-05       Impact factor: 5.594

5.  Evaluation of Ahmed glaucoma valve implantation through a needle-generated scleral tunnel in Mexican children with glaucoma.

Authors:  Oscar Albis-Donado; Félix Gil-Carrasco; Rafael Romero-Quijada; Ravi Thomas
Journal:  Indian J Ophthalmol       Date:  2010 Sep-Oct       Impact factor: 1.848

Review 6.  [Glaucoma drainage devices].

Authors:  H Thieme
Journal:  Ophthalmologe       Date:  2009-12       Impact factor: 1.059

7.  Intraocular pressure control after the implantation of a second Ahmed glaucoma valve.

Authors:  Jesús Jiménez-Román; Félix Gil-Carrasco; Vital Paulino Costa; Rui Barroso Schimiti; Fabián Lerner; Priscila Rezende Santana; Jose Paulo Cabral Vascocellos; Armando Castillejos-Chévez; Mauricio Turati; Karina Fabre-Miranda
Journal:  Int Ophthalmol       Date:  2015-09-03       Impact factor: 2.031

8.  [Tube versus trabeculectomy study].

Authors:  H Thieme; L Choritz; C Schuart; T Wecke
Journal:  Ophthalmologe       Date:  2013-08       Impact factor: 1.059

Review 9.  Modern concepts in antiglaucomatous implant surgery.

Authors:  T S Dietlein; J Jordan; C Lueke; G K Krieglstein
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2008-08-06       Impact factor: 3.117

10.  The efficacy of Ahmed glaucoma valve drainage devices in cases of adult refractory glaucoma in Indian eyes.

Authors:  Jitendra K S Parihar; Devendra P Vats; Rakesh Maggon; Vijay Mathur; Anirudh Singh; Sanjay K Mishra
Journal:  Indian J Ophthalmol       Date:  2009 Sep-Oct       Impact factor: 1.848

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.