Literature DB >> 16872916

Direct electrochemistry behavior of cytochrome c/L-cysteine modified electrode and its electrocatalytic oxidation to nitric oxide.

Yun-Chun Liu1, Shi-Qiang Cui, Jun Zhao, Zhou-Sheng Yang.   

Abstract

Cytochrome c (Cyt c) was successfully immobilized on L-cysteine modified gold electrode by multicyclic voltammetry method. The electrochemical behavior of Cyt c on the L-cysteine modified electrode was explored. In 0.10 M, pH 7.0 phosphate buffer solution (PBS), Cyt c showed a quasi-reversible electrochemical redox behavior with E(pc)=0.180 V, E(pa)=0.208 V (versus Ag/AgCl). The Cyt c/L-cysteine modified electrode gave an excellent electrocatalytic activity towards the oxidation of nitric oxide, and the catalysis currents were proportional to the nitric oxide concentration in the range of 7.0 x 10(-7) to 1.0 x 10(-5) M, the linear regression equation is I (microA)=-0.124-0.003 C(NO) (microM), with a correlation coefficient 0.996, The detection limit was 3.0 x 10(-7) M (times the ratio of signal to noise, S/N=3).

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16872916     DOI: 10.1016/j.bioelechem.2006.06.001

Source DB:  PubMed          Journal:  Bioelectrochemistry        ISSN: 1567-5394            Impact factor:   5.373


  1 in total

1.  New Disposable Nitric Oxide Sensor Fabrication Using GaN Nanowires.

Authors:  Bagavath Chandran; Kumar Janakiraman
Journal:  ACS Omega       Date:  2019-10-11