Literature DB >> 16872337

Comparative evaluation of oral fluorescein angiography using the confocal scanning laser ophthalmoscope and digital fundus camera with intravenous fluorescein angiography using the digital fundus camera.

Raj Vardhan Azad1, Bipul Baishya, Nikhil Pal, Yog Raj Sharma, Atul Kumar, Rajpal Vohra.   

Abstract

BACKGROUND: To study the efficacy of oral fluorescein angiography (FA) with confocal scanning laser ophthalmoscope (CSLO).
METHODS: Ten patients each of choroidal neovascular membrane, central serous retinopathy, diabetic retinopathy and five normal subjects were evaluated with group 1 - intravenous FA using digital fundus camera (DFC); group 2 - oral FA using DFC; and group 3 - oral FA using CSLO.
RESULTS: Third-order branch vessels were identified in 85.7% eyes in group 3 versus 51.4% in group 2 (P = 0.004), image quality was comparable to intravenous FA in 77.1% in group 3 versus 48.5% in group 2 (P = 0.02) and margin delineation was better in 80% eyes in group 3 versus 35% in group 2 (P = 0.01). The foveal avascular zone was clear and intact in 54.2% eyes in group 3 versus 37.1% in group 2 (P = 0.14) and 57.1% in group 1 (P = 0.8).
CONCLUSION: Oral FA using CSLO is superior to oral FA using DFC and comparable to intravenous FA using DFC in terms of image quality, branch retinal vessel identification and margin delineation.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16872337     DOI: 10.1111/j.1442-9071.2006.01243.x

Source DB:  PubMed          Journal:  Clin Exp Ophthalmol        ISSN: 1442-6404            Impact factor:   4.207


  2 in total

1.  Safety and efficacy of oral fluorescein angiography in detecting macular edema in comparison with spectral-domain optical coherence tomography.

Authors:  Giulio Barteselli; Jay Chhablani; Su Na Lee; Haiyan Wang; Sharif El Emam; Igor Kozak; Lingyun Cheng; Dirk-Uwe Bartsch; Stanley Azen; William R Freeman
Journal:  Retina       Date:  2013-09       Impact factor: 4.256

2.  In vivo imaging of human retinal microvasculature using adaptive optics scanning light ophthalmoscope fluorescein angiography.

Authors:  Alexander Pinhas; Michael Dubow; Nishit Shah; Toco Y Chui; Drew Scoles; Yusufu N Sulai; Rishard Weitz; Joseph B Walsh; Joseph Carroll; Alfredo Dubra; Richard B Rosen
Journal:  Biomed Opt Express       Date:  2013-07-12       Impact factor: 3.732

  2 in total