Literature DB >> 16870423

Self-assembled PEG monolayer based SPR immunosensor for label-free detection of insulin.

K Vengatajalabathy Gobi1, Hiroyuki Iwasaka, Norio Miura.   

Abstract

A simple and rapid continuous-flow immunosensor based on surface plasmon resonance (SPR) has been developed for detection of insulin as low as 1 ng ml-1 (ppb) with a response time of less than 5 min. At first, a heterobifunctional oligo(ethyleneglycol)-dithiocarboxylic acid derivative (OEG-DCA) containing dithiol and carboxyl end groups was used to functionalize the thin Au-film of SPR chip. Insulin was covalently bound to the Au-thiolate monolayer of OEG-DCA for activating the sensor surface to immunoaffinity interactions. An on-line competitive immunosensing principle is examined for detection of insulin, in which the direct affinity binding of anti-insulin antibody to the insulin on sensor surface is examined in the presence and absence of various concentrations of insulin. Immunoreaction of anti-insulin antibody with the sensor surface was optimized with reference to antibody concentration, sample analysis time and flow-rate to provide the desired detection limit and determination range. With the immunosensor developed, the lowest detectable concentration of insulin is 1 ng ml-1 and the determination range covers a wide concentration of 1-300 ng ml-1. The developed OEG-monolayer based sensor chip exhibited high resistance to non-specific adsorption of proteins, and an uninterrupted highly sensitive detection of insulin from insulin-impregnated serum samples has been demonstrated. After an immunoreaction cycle, active sensor surface was regenerated simply by a brief flow of an acidic buffer (glycine.HCl; pH 2.0) for less than 1 min. A same sensor chip was found reusable for more than 25 cycles without an appreciable change in the original sensor activity.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16870423     DOI: 10.1016/j.bios.2006.06.012

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  18 in total

1.  Surface plasmon resonance aided electrochemical immunosensor for CK-MB determination in undiluted serum samples.

Authors:  Fernando Garay; Greggory Kisiel; Aiping Fang; Erno Lindner
Journal:  Anal Bioanal Chem       Date:  2010-05-08       Impact factor: 4.142

2.  Noble metal nanostructures in optical biosensors: Basics, and their introduction to anti-doping detection.

Authors:  Hedieh Malekzad; Parham Sahandi Zangabad; Hadi Mohammadi; Mohsen Sadroddini; Zahra Jafari; Niloofar Mahlooji; Somaye Abbaspour; Somaye Gholami; Mana Ghanbarpoor; Rahim Pashazadeh; Ali Beyzavi; Mahdi Karimi; Michael R Hamblin
Journal:  Trends Analyt Chem       Date:  2018-01-05       Impact factor: 12.296

3.  Magnetic Optical Microarray Imager for Diagnosing Type of Diabetes in Clinical Blood Serum Samples.

Authors:  Vini Singh; Cassandra Rodenbaugh; Sadagopan Krishnan
Journal:  ACS Sens       Date:  2016-02-18       Impact factor: 7.711

Review 4.  Electrochemical and surface plasmon insulin assays on clinical samples.

Authors:  Vini Singh; Sadagopan Krishnan
Journal:  Analyst       Date:  2018-03-26       Impact factor: 4.616

5.  An electrochemical aptamer-based assay for femtomolar determination of insulin using a screen printed electrode modified with mesoporous carbon and 1,3,6,8-pyrenetetrasulfonate.

Authors:  Mahmoud Amouzadeh Tabrizi; Mojtaba Shamsipur; Reza Saber; Saeed Sarkar; Maryam Besharati
Journal:  Mikrochim Acta       Date:  2017-12-18       Impact factor: 5.833

6.  Microfluidic platform for assessing pancreatic islet functionality through dielectric spectroscopy.

Authors:  K Heileman; J Daoud; C Hasilo; M Gasparrini; S Paraskevas; M Tabrizian
Journal:  Biomicrofluidics       Date:  2015-08-27       Impact factor: 2.800

7.  Bioconjugation strategies for microtoroidal optical resonators.

Authors:  Heather K Hunt; Carol Soteropulos; Andrea M Armani
Journal:  Sensors (Basel)       Date:  2010-10-18       Impact factor: 3.576

8.  Immunosensor incorporating anti-His (C-term) IgG F(ab') fragments attached to gold nanorods for detection of His-tagged proteins in culture medium.

Authors:  Michal Wąsowicz; Małgorzata Milner; Dorota Radecka; Krystyna Grzelak; Hanna Radecka
Journal:  Sensors (Basel)       Date:  2010-06-01       Impact factor: 3.576

9.  Passive fluidic chip composed of integrated vertical capillary tubes developed for on-site SPR immunoassay analysis targeting real samples.

Authors:  Tsutomu Horiuchi; Toru Miura; Yuzuru Iwasaki; Michiko Seyama; Suzuyo Inoue; Jun-ichi Takahashi; Tsuneyuki Haga; Emi Tamechika
Journal:  Sensors (Basel)       Date:  2012-05-29       Impact factor: 3.576

10.  Floating chip mounting system driven by repulsive force of permanent magnets for multiple on-site SPR immunoassay measurements.

Authors:  Tsutomu Horiuchi; Tatsuya Tobita; Toru Miura; Yuzuru Iwasaki; Michiko Seyama; Suzuyo Inoue; Jun-ichi Takahashi; Tsuneyuki Haga; Emi Tamechika
Journal:  Sensors (Basel)       Date:  2012-10-17       Impact factor: 3.576

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.