Literature DB >> 16870422

Optical immunosensor for fast and sensitive detection of DDT and related compounds in river water samples.

E Mauriz1, A Calle, J J Manclús, A Montoya, A Hildebrandt, D Barceló, L M Lechuga.   

Abstract

A surface plasmon resonance (SPR) based immunosensor has been developed for the monitoring of environmentally persistent pollutants like DDT, its metabolites and analogues in real water samples. A reusable immunosurface is provided via the covalent attachment of the analyte derivative to a self-assembled alkanethiol monolayer formed onto the SPR gold-thin layer. The regeneration of the sensor surface allowed the performance of 270 assay cycles within an analysis time of 20 min for each assay cycle. Immunoassays based on a binding inhibition format were performed by using two monoclonal antibodies (MAbs) with different selectivity. Low limits of detection (LODs), in the sub-nanogram per litre range, were attained for DDT-selective (15 ng L-1) and DDT group-selective immunoassays (31 ng L-1). Both assays were carried out in spiked river water samples without significant effect of the matrix. SPR measurements were validated using gas-chromatography-mass spectrometry. The comparison between methods was in good agreement showing an excellent correlation coefficient (r2=0.995). The SPR analysis of DDT proved to be three times more sensitive than colorimetric ELISAs without the need of labelling and a much lower time of response. Our SPR biosensor portable platform (beta-SPR) is already commercialised by the company SENSIA, S.L. (Spain).

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16870422     DOI: 10.1016/j.bios.2006.06.016

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  5 in total

1.  Current advancements of magnetic nanoparticles in adsorption and degradation of organic pollutants.

Authors:  Mazhar Ul-Islam; Muhammad Wajid Ullah; Shaukat Khan; Shehrish Manan; Waleed Ahmad Khattak; Wasi Ahmad; Nasrullah Shah; Joong Kon Park
Journal:  Environ Sci Pollut Res Int       Date:  2017-04-04       Impact factor: 4.223

Review 2.  Recent trends in monitoring of European water framework directive priority substances using micro-sensors: a 2007-2009 review.

Authors:  Philippe Namour; Mathieu Lepot; Nicole Jaffrezic-Renault
Journal:  Sensors (Basel)       Date:  2010-08-26       Impact factor: 3.576

Review 3.  State-of-the-art of (bio)chemical sensor developments in analytical Spanish groups.

Authors:  María Reyes Plata; Ana María Contento; Angel Ríos
Journal:  Sensors (Basel)       Date:  2010-03-24       Impact factor: 3.576

4.  Improved sensitivity of polychlorinated-biphenyl-orientated porous-ZnO surface photovoltage sensors from chemisorption-formed ZnO-CuPc composites.

Authors:  Mingtao Li; Guowen Meng; Qing Huang; Shile Zhang
Journal:  Sci Rep       Date:  2014-03-05       Impact factor: 4.379

Review 5.  Recent Progress in Biosensors for Environmental Monitoring: A Review.

Authors:  Celine I L Justino; Armando C Duarte; Teresa A P Rocha-Santos
Journal:  Sensors (Basel)       Date:  2017-12-15       Impact factor: 3.576

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.