Literature DB >> 16868297

Identification of patients at low risk for recurrent venous thromboembolism by measuring thrombin generation.

Gregor Hron1, Marietta Kollars, Bernd R Binder, Sabine Eichinger, Paul A Kyrle.   

Abstract

CONTEXT: Screening of patients with venous thromboembolism (VTE) for thrombophilic risk factors is common clinical practice. Because of the large number of risk factors, assessing the risk of recurrence in an individual patient is complex. A method covering multicausal thrombophilia is therefore required.
OBJECTIVE: To investigate the relationship between recurrence of VTE and a simple global coagulation assay measuring thrombin generation. DESIGN, SETTING, AND PARTICIPANTS: Prospective cohort study of 914 patients with first spontaneous VTE who were followed up for an average of 47 months after discontinuation of vitamin K antagonist therapy. The study was conducted at the Department of Internal Medicine I, Medical University of Vienna, Vienna, Austria, between July 1992 and July 2005. Thrombin generation was measured by a commercially available assay system. Patients with a previous or secondary VTE; antithrombin, protein C, or protein S deficiencies; presence of lupus anticoagulant; cancer; or pregnancy were excluded. MAIN OUTCOME MEASURE: Objectively documented symptomatic recurrent VTE.
RESULTS: Venous thromboembolism recurred in 100 patients (11%). Patients without recurrent VTE had lower thrombin generation than patients with recurrence (mean [SD], 349.2 [108.0] nM vs 419.5 [110.5] nM, respectively; P<.001). Compared with patients who had thrombin generation greater than 400 nM, the relative risk (RR) of recurrence was 0.42 (95% confidence interval [CI], 0.26-0.67; P<.001) in patients with values between 400 nM and 300 nM; for patients with lower values, the RR was 0.37 (95% CI, 0.21-0.66; P = .001). After 4 years, the probability of recurrence was 6.5% (95% CI, 4.0%-8.9%) among patients with thrombin generation less than 400 nM compared with 20.0% (95% CI, 14.9%-25.1%) among patients with higher values (P<.001). Patients with thrombin generation less than 400 nM, representing two thirds of patients, had a 60% lower RR of recurrence than those with greater values (RR, 0.40; 95% CI, 0.27-0.60; P<.001).
CONCLUSION: Measurement of thrombin generation identifies patients at low risk for recurrent VTE.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16868297     DOI: 10.1001/jama.296.4.397

Source DB:  PubMed          Journal:  JAMA        ISSN: 0098-7484            Impact factor:   56.272


  87 in total

1.  Hypercoagulability in patients with type 2 diabetes mellitus detected by a thrombin generation assay.

Authors:  Armando Tripodi; Adriana Branchi; Veena Chantarangkul; Marigrazia Clerici; Giuliana Merati; Andrea Artoni; Pier Mannuccio Mannucci
Journal:  J Thromb Thrombolysis       Date:  2011-02       Impact factor: 2.300

2.  Endogenous thrombin potential changes during the first cycle of oral contraceptive use.

Authors:  Carolyn L Westhoff; Malcolm C Pike; Serge Cremers; Andrew Eisenberger; Stella Thomassen; Jan Rosing
Journal:  Contraception       Date:  2017-01-11       Impact factor: 3.375

Review 3.  Predicting the risk of recurrent venous thromboembolism (VTE).

Authors:  Michael B Streiff
Journal:  J Thromb Thrombolysis       Date:  2015-04       Impact factor: 2.300

4.  Usefulness of factor V Leiden mutation testing in clinical practice.

Authors:  Ellen Ø Blinkenberg; Ann-Helen Kristoffersen; Sverre Sandberg; Vidar M Steen; Gunnar Houge
Journal:  Eur J Hum Genet       Date:  2010-03-24       Impact factor: 4.246

5.  Warfarin dose requirement in patients having severe thrombosis or thrombophilia.

Authors:  Tuukka A Helin; Lotta Joutsi-Korhonen; Heidi Asmundela; Mikko Niemi; Arto Orpana; Riitta Lassila
Journal:  Br J Clin Pharmacol       Date:  2019-06-17       Impact factor: 4.335

6.  Venous thromboembolism risk factor assessment and prophylaxis.

Authors:  P K Henke; C J Pannucci
Journal:  Phlebology       Date:  2010-10       Impact factor: 1.740

7.  Association of thrombin generation potential with platelet PAR-1 regulation and P-selectin expression in patients on dual antiplatelet therapy.

Authors:  Roza Badr Eslam; Florian Posch; Irene M Lang; Thomas Gremmel; Beate Eichelberger; Cihan Ay; Simon Panzer
Journal:  J Cardiovasc Transl Res       Date:  2014-01-17       Impact factor: 4.132

8.  The effect of high circulating estradiol levels on thrombin generation during in vitro fertilization.

Authors:  Kathleen E Brummel-Ziedins; Matthew Gissel; Charles Francis; John Queenan; Kenneth G Mann
Journal:  Thromb Res       Date:  2009-03-17       Impact factor: 3.944

9.  Bioactivity of enoxaparin in critically ill patients with normal renal function.

Authors:  Ghazaleh Gouya; Stefan Palkovits; Stylianos Kapiotis; Christian Madl; Gottfried Locker; Alexander Stella; Michael Wolzt; Gottfried Heinz
Journal:  Br J Clin Pharmacol       Date:  2012-11       Impact factor: 4.335

10.  Body mass index reduction improves the baseline procoagulant imbalance of obese subjects.

Authors:  Armando Tripodi; Massimo Primignani; Sara Badiali; Fausto de Ruberto; Paola Granelli; Giulia Tosetti; Marigrazia Clerici; Lidia Padovan; Veena Chantarangkul; Erica Scalambrino; Flora Peyvandi
Journal:  J Thromb Thrombolysis       Date:  2019-07       Impact factor: 2.300

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.