Literature DB >> 16868170

Evaluation of MR/fluoroscopy-guided portosystemic shunt creation in a swine model.

Aravind Arepally1, Parag V Karmarkar, Di Qian, Brad Barnett, Ergin Atalar.   

Abstract

PURPOSE: To evaluate three different percutaneous portosystemic shunts created with magnetic resonance (MR) imaging and fluoroscopy guidance in a swine model.
MATERIALS AND METHODS: In stage 1 of the experiment, an active MR intravascular needle system was created for needle tracking and extracaval punctures. Twenty inferior vena cava (IVC)/superior mesenteric vein (SMV)/portal vein (PV) punctures were performed in 10 swine (weight, 40-45 kg) in a 1.5-T short-bore interventional MR imager. With use of a real-time MR imaging sequence, the needle was guided through the IVC and into the SMV or PV (N = 20 punctures). After confirmation, a wire was advanced into the portal venous system under MR imaging guidance (N = 20). In stage 2, animals were transferred to the radiographic fluoroscopy suite for deployment of shunts. Three different shunts were evaluated in this study: (i) a commercial stent-graft, (ii) a prototype bridging stent, and (iii) a prototype nitinol vascular anastomotic device. Postprocedural necropsy was performed in all animals.
RESULTS: Successful MR-guided IVC/SMV punctures were performed in all 20 procedures (100%). All three shunts were deployed. Stent-grafts had the poorest mechanism for securing a shunt. The vascular anastomotic device and the bridging stent had more secure anchoring mechanisms but also had higher technical failure rates (50% and 40%, respectively). When deployed successfully, the vascular anastomotic device resulted in no bleeding at the sites of punctures at necropsy.
CONCLUSION: Percutaneous shunts and vascular anastomoses between the portal mesenteric venous system and IVC were successfully created with use of a combination of MR imaging and conventional fluoroscopy for guidance.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16868170     DOI: 10.1097/01.RVI.0000228493.07075.FC

Source DB:  PubMed          Journal:  J Vasc Interv Radiol        ISSN: 1051-0443            Impact factor:   3.464


  6 in total

1.  Liver acquisition with volume acceleration flex on 70-cm wide-bore and 60-cm conventional-bore 3.0-T MRI.

Authors:  Shigeyoshi Saito; Keiko Tanaka; Takashi Hashido
Journal:  Radiol Phys Technol       Date:  2016-01-06

Review 2.  Interventional cardiovascular magnetic resonance imaging.

Authors:  Venkatesh K Raman; Robert J Lederman
Journal:  Trends Cardiovasc Med       Date:  2007-08       Impact factor: 6.677

3.  MR-guided liver biopsy within a short, wide-bore 1.5 Tesla MR system.

Authors:  Joerg Stattaus; Stefan Maderwald; Hideo A Baba; Guido Gerken; Joerg Barkhausen; Michael Forsting; Mark E Ladd
Journal:  Eur Radiol       Date:  2008-07-19       Impact factor: 5.315

Review 4.  Magnetic resonance imaging-guided vascular interventions.

Authors:  Cengizhan Ozturk; Michael Guttman; Elliot R McVeigh; Robert J Lederman
Journal:  Top Magn Reson Imaging       Date:  2005-10

Review 5.  Metabolic flux between organs measured by arteriovenous metabolite gradients.

Authors:  Hosung Bae; Katie Lam; Cholsoon Jang
Journal:  Exp Mol Med       Date:  2022-09-08       Impact factor: 12.153

Review 6.  The Future of Paediatric Heart Interventions: Where Will We Be in 2030?

Authors:  Tomohito Kogure; Shakeel A Qureshi
Journal:  Curr Cardiol Rep       Date:  2020-10-09       Impact factor: 2.931

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.