| Literature DB >> 16867298 |
Steven J Russell1, Lori Winnemuller, Janice E Camp, Peter W Johnson.
Abstract
The objective of this study was to compare the results of the NIOSH, ACGIH TLV, Snook, 3DSSPP and WA L&I lifting assessment instruments when applied to a uniform task (lifting and lowering milk cases with capacities of 15 and 23l). To enable comparisons between the various lifting assessment instruments, the outputs of each method were converted to an exposure index similar to the NIOSH Lifting Index. All instruments showed higher exposures associated with lifting the 23l cases versus the 15l cases. The NIOSH, ACGIH TLV and Snook methods were similar in their results with respect to the pattern of exposure over various height levels and the differences in exposures associated with lifting 15 and 23l cases. However, the WA L&I and 3DSSPP predicted substantially lower exposures. The reasons for instrument differences are presented so that practitioners can better select the methods they need and interpret the results appropriately.Entities:
Mesh:
Year: 2006 PMID: 16867298 DOI: 10.1016/j.apergo.2005.12.006
Source DB: PubMed Journal: Appl Ergon ISSN: 0003-6870 Impact factor: 3.661