Literature DB >> 16866565

Rationale for the combination of nuclear medicine with magnetic resonance for pre-clinical imaging.

Douglas J Wagenaar1, Maciej Kapusta, Junqiang Li, Bradley E Patt.   

Abstract

Multi-modality combinations of SPECT/CT and PET/CT have proven to be highly successful in the clinic and small animal SPECT/CT and PET/CT are becoming the norm in the research and drug development setting. However, the use of ionizing radiation from a high-resolution CT scanner is undesirable in any setting and particularly in small animal imaging (SAI), in laboratory experiments where it can result in radiation doses of sufficient magnitude that the experimental results can be influenced by the organism's response to radiation. The alternative use of magnetic resonance (MR) would offer a high-resolution, non-ionizing method for anatomical imaging of laboratory animals. MR brings considerably more than its 3D anatomical capability, especially regarding the imaging of laboratory animals. Dynamic MR imaging techniques can facilitate studies of perfusion, oxygenation, and diffusion amongst others. Further, MR spectroscopy can provide images that can be related to the concentration of endogenous molecules in vivo. MR imaging of injected contrast agents extends MR into the domain of molecular imaging. In combination with nuclear medicine (NM) SPECT and PET modalities in small animal imaging, MR would facilitate studies of dynamic processes such as biodistribution, pharmacokinetics, and pharmacodynamics. However, the detectors for nearly all PET and SPECT systems are still based on vacuum tube technology, namely: photomultiplier tubes (PMT's) in which the signal is generated by transporting electrons over a substantial distance within an evacuated glass tube, making them inoperable in even small magnetic fields. Thus the combination of SPECT or PET with MR has not been practical until the recent availability of semiconductor detectors such as silicon avalanche photodiodes (APD's) for PET and CdZnTe (CZT) detectors for SPECT coupled with the availability of high-density low noise ASIC electronics to read out the semiconductor detectors. The strong advantage of these technologies over PMT's is their insensitivity to magnetic fields which makes their use in co-axial multi-modality nuclear medicine/magnetic resonance instrumentation possible.

Entities:  

Mesh:

Year:  2006        PMID: 16866565     DOI: 10.1177/153303460600500406

Source DB:  PubMed          Journal:  Technol Cancer Res Treat        ISSN: 1533-0338


  11 in total

Review 1.  PET and SPECT in cardiovascular molecular imaging.

Authors:  Lawrence W Dobrucki; Albert J Sinusas
Journal:  Nat Rev Cardiol       Date:  2009-11-24       Impact factor: 32.419

2.  Translational imaging endpoints to predict treatment response to novel targeted anticancer agents.

Authors:  Natalie J Serkova
Journal:  Drug Resist Updat       Date:  2011-06-02       Impact factor: 18.500

3.  A SPECT Camera for Combined MRI and SPECT for Small Animals.

Authors:  D Meier; D J Wagenaar; S Chen; J Xu; J Yu; B M W Tsui
Journal:  Nucl Instrum Methods Phys Res A       Date:  2011-10-01       Impact factor: 1.455

4.  Feasibility study of a unilateral RF array coil for MR-scintimammography.

Authors:  Seunghoon Ha; Mark J Hamamura; Werner W Roeck; James Hugg; Douglas J Wagenaar; Dirk Meier; Bradley E Patt; Orhan Nalcioglu
Journal:  Phys Med Biol       Date:  2011-10-05       Impact factor: 3.609

5.  Initial Investigation of preclinical integrated SPECT and MR imaging.

Authors:  Mark J Hamamura; Seunghoon Ha; Werner W Roeck; Douglas J Wagenaar; Dirk Meier; Bradley E Patt; Orhan Nalcioglu
Journal:  Technol Cancer Res Treat       Date:  2010-02

6.  Multimodality rodent imaging chambers for use under barrier conditions with gas anesthesia.

Authors:  Chris Suckow; Claudia Kuntner; Patrick Chow; Robert Silverman; Arion Chatziioannou; David Stout
Journal:  Mol Imaging Biol       Date:  2008-08-05       Impact factor: 3.488

7.  Is absolute quantification of dopaminergic neurotransmission studies with 123I SPECT ready for clinical use?

Authors:  Habib Zaidi; Georges El Fakhri
Journal:  Eur J Nucl Med Mol Imaging       Date:  2008-07       Impact factor: 9.236

8.  The future of hybrid imaging-part 3: PET/MR, small-animal imaging and beyond.

Authors:  Thomas Beyer; Lutz S Freudenberg; Johannes Czernin; David W Townsend
Journal:  Insights Imaging       Date:  2011-03-25

9.  Radionuclide-based molecular imaging allows CAR-T cellular visualization and therapeutic monitoring.

Authors:  Fuqiang Shao; Yu Long; Hao Ji; Dawei Jiang; Ping Lei; Xiaoli Lan
Journal:  Theranostics       Date:  2021-05-03       Impact factor: 11.556

Review 10.  Multimodality reporter gene imaging: Construction strategies and application.

Authors:  Mengting Li; Yichun Wang; Mei Liu; Xiaoli Lan
Journal:  Theranostics       Date:  2018-04-18       Impact factor: 11.556

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.