Literature DB >> 16864670

Jugular vein catheter placement: histologic features and development of catheter-related (fibrin) sheaths in a swine model.

Andrew R Forauer1, Constantine G A Theoharis, Narasimham L Dasika.   

Abstract

PURPOSE: To evaluate the development and histologic features of jugular vein catheter-related (fibrin) sheaths in a swine model.
MATERIALS AND METHODS: The proposal was approved by the University Committee on the Use and Care of Animals. Tunneled silicone 7-F catheters were placed via a jugular vein in eight swine. The animals were separated into four groups of two pigs each according to catheter indwelling times of 7, 14, 30, and 45 days. After the animals were sacrificed, the catheter, access vein, and cranial vena cava were dissected, removed en bloc, and fixed in formalin. Histologic evaluation was performed by using standard light microscopy on hematoxylin-eosin stained specimens; immunohistochemistry was also performed to confirm specific cell populations.
RESULTS: Catheter-related sheaths that covered 33%-100% of the intravascular catheter length were identified in all eight catheter specimens. After 7 days, catheters had a partial or circumferential mixed cellular and noncellular covering consisting of smooth muscle cells, thrombus, and areas with endothelial cell populations. Sheaths from catheters excised at 14 days were characterized by prominent endothelial cell and smooth muscle cell proliferation. Catheters excised at 30 and 45 days showed less prominent cellularity and more prominent collagen content, in a well-developed sheath, than did those excised at 7 and 14 days. With longer catheter indwelling times, an endothelial layer, indistinguishable from the adjacent vein wall, covered the catheter surface.
CONCLUSION: The sheath that develops around central venous catheters in the swine model consists of cellular and noncellular components. A substantial proportion of the sheath is made up of a smooth muscle cell and collagen layer with overlying endothelial cells. RSNA, 2006

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16864670     DOI: 10.1148/radiol.2402031129

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  17 in total

1.  Vascular access port implantation and serial blood sampling in a Gottingen minipig (Sus scrofa domestica) model of acute radiation injury.

Authors:  Maria Moroni; Thea V Coolbaugh; Jennifer M Mitchell; Eric Lombardini; Krinon D Moccia; Larry J Shelton; Vitaly Nagy; Mark H Whitnall
Journal:  J Am Assoc Lab Anim Sci       Date:  2011-01       Impact factor: 1.232

2.  Dysfunction of a port-catheter system percutaneously implanted for hepatic arterial infusion chemotherapy due to a fibrin sheath.

Authors:  Takuji Yamagami; Tomohiro Matsumoto; Rika Yoshimatsu; Tsunehiko Nishimura
Journal:  Clin J Gastroenterol       Date:  2008-12-25

3.  Clinical and Regulatory Considerations for Central Venous Catheters for Hemodialysis.

Authors:  Douglas M Silverstein; Scott O Trerotola; Timothy Clark; Garth James; Wing Ng; Amy Dwyer; Marius C Florescu; Roman Shingarev; Stephen R Ash
Journal:  Clin J Am Soc Nephrol       Date:  2018-10-11       Impact factor: 8.237

Review 4.  Update on Insertion and Complications of Central Venous Catheters for Hemodialysis.

Authors:  Peter R Bream
Journal:  Semin Intervent Radiol       Date:  2016-03       Impact factor: 1.513

5.  Thromboprophylaxis with rivaroxaban in patients with malignancy and central venous lines (TRIM-Line): A two-center open-label pilot randomized controlled trial.

Authors:  Rick Ikesaka; Deborah Siegal; Ranjeeta Mallick; Tzu-Fei Wang; Deborah Witham; Carolyn Webb; Marc Carrier
Journal:  Res Pract Thromb Haemost       Date:  2021-05-05

6.  Minimally Invasive Monitoring of Chronic Central Venous Catheter Patency in Mice Using Digital Subtraction Angiography (DSA).

Authors:  Giovanna Figueiredo; Teresa Fiebig; Stefanie Kirschner; Omid Nikoubashman; Lisa Kabelitz; Ahmed Othman; Andrea Nonn; Martin Kramer; Marc A Brockmann
Journal:  PLoS One       Date:  2015-06-22       Impact factor: 3.240

7.  Endoluminal dilatation for embedded hemodialysis catheters: A case-control study of factors associated with embedding and clinical outcomes.

Authors:  Hari Talreja; Stephen Edward Ryan; Janet Graham; Manish M Sood; Adnan Hadziomerovic; Edward Clark; Swapnil Hiremath
Journal:  PLoS One       Date:  2017-03-27       Impact factor: 3.240

8.  Fibrin sheath of a peripherally inserted central catheter undepicted with gray-scale (real-time B-mode) ultrasonography: A case report.

Authors:  Naoko Mogi; Motoo Nakagawa; Hidekazu Matsumae; Ayako Hattori; Masashi Shimohira; Yuta Shibamoto
Journal:  Radiol Case Rep       Date:  2018-03-06

9.  Blood collection in unstressed, conscious, and freely moving mice through implantation of catheters in the jugular vein: a new simplified protocol.

Authors:  Annie Y Park; Paul M Plotsky; Truyen D Pham; Karel Pacak; Brandi M Wynne; Susan M Wall; Yoskaly Lazo-Fernandez
Journal:  Physiol Rep       Date:  2018-11

10.  Risk factors for venous port migration in a single institute in Taiwan.

Authors:  Wen-Chieh Fan; Cheng-Han Wu; Ming-Ju Tsai; Ying-Ming Tsai; Hsu-Liang Chang; Jen-Yu Hung; Pei-Huan Chen; Chih-Jen Yang
Journal:  World J Surg Oncol       Date:  2014-01-14       Impact factor: 2.754

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.