Literature DB >> 16862409

New technologies to reduce pediatric radiation doses.

Philipp Bernhardt1, Markus Lendl, Frank Deinzer.   

Abstract

X-ray dose reduction in pediatrics is particularly important because babies and children are very sensitive to radiation exposure. We present new developments to further decrease pediatric patient dose. With the help of an advanced exposure control, a constant image quality can be maintained for all patient sizes, leading to dose savings for babies and children of up to 30%. Because objects of interest are quite small and the speed of motion is high in pediatric patients, short pulse widths down to 4 ms are important to reduce motion blurring artifacts. Further, a new noise-reduction algorithm is presented that detects and processes signal and noise in different frequency bands, generating smooth images without contrast loss. Finally, we introduce a super-resolution technique: two or more medical images, which are shifted against each other in a subpixel region, are combined to resolve structures smaller than the size of a single pixel. Advanced exposure control, short exposure times, noise reduction and super-resolution provide improved image quality, which can also be invested to save radiation exposure. All in all, the tools presented here offer a large potential to minimize the deterministic and stochastic risks of radiation exposure.

Entities:  

Mesh:

Year:  2006        PMID: 16862409      PMCID: PMC2663645          DOI: 10.1007/s00247-006-0212-4

Source DB:  PubMed          Journal:  Pediatr Radiol        ISSN: 0301-0449


  2 in total

1.  Superresolution in MRI: application to human white matter fiber tract visualization by diffusion tensor imaging.

Authors:  S Peled; Y Yeshurun
Journal:  Magn Reson Med       Date:  2001-01       Impact factor: 4.668

2.  Fast and robust multiframe super resolution.

Authors:  Sina Farsiu; M Dirk Robinson; Michael Elad; Peyman Milanfar
Journal:  IEEE Trans Image Process       Date:  2004-10       Impact factor: 10.856

  2 in total
  6 in total

1.  Joint quality improvement guidelines for pediatric arterial access and arteriography: from the Societies of Interventional Radiology and Pediatric Radiology.

Authors:  Manraj K S Heran; Francis Marshalleck; Michael Temple; Clement J Grassi; Bairbre Connolly; Richard B Towbin; Kevin M Baskin; Josee Dubois; Mark J Hogan; Sanjoy Kundu; Donald L Miller; Derek J Roebuck; Steven C Rose; David Sacks; Manrita Sidhu; Michael J Wallace; Darryl A Zuckerman; John F Cardella
Journal:  Pediatr Radiol       Date:  2010-02

Review 2.  Customized imaging for children and obese people: key issues and strategies.

Authors:  Giovanni Lucignani
Journal:  Eur J Nucl Med Mol Imaging       Date:  2006-11       Impact factor: 9.236

3.  Super-resolution variable-dose imaging in digital radiography: quality and dose reduction with a fluoroscopic flat-panel detector.

Authors:  Leonard Berliner; Alfonso Buffa
Journal:  Int J Comput Assist Radiol Surg       Date:  2011-02-05       Impact factor: 2.924

4.  Tantalum-specific contrast-to-noise ratio or conventional detector dose-driven exposure control in angiography: radiation dose and image quality evaluation in a porcine model.

Authors:  Thomas Werncke; Timo Christian Meine; Jan B Hinrichs; Sabine K Maschke; Lena Sophie Becker; Inga Brüsch; Regina Rumpel; Frank K Wacker; Bernhard C Meyer
Journal:  Eur Radiol Exp       Date:  2022-05-17

5.  Evaluation of the lung in children with suspected pneumonia: usefulness of ultrasonography.

Authors:  D Iuri; A De Candia; M Bazzocchi
Journal:  Radiol Med       Date:  2008-10-25       Impact factor: 3.469

6.  Emergency department visits, use of imaging, and drugs for urolithiasis have increased in the United States.

Authors:  Chyng-Wen Fwu; Paul W Eggers; Paul L Kimmel; John W Kusek; Ziya Kirkali
Journal:  Kidney Int       Date:  2013-01-02       Impact factor: 10.612

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.