Literature DB >> 16861690

Mechanisms leading to reversible mechanical dysfunction in severe CAD: alternatives to myocardial stunning.

Alejandro N Mazzadi1, Xavier André-Fouët, Nicolas Costes, Pierre Croisille, Didier Revel, Marc F Janier.   

Abstract

Patients with severe chronic coronary artery disease (CAD) exhibit a highly altered myocardial pattern of perfusion, metabolism, and mechanical performance. In this context, the diagnosis of stunning remains elusive not only because of methodological and logistic considerations, but also because of the pathophysiological characteristics of the myocardium of these patients. In addition, a number of alternative pathophysiological mechanisms may act by mimicking the functional manifestations usually attributed to stunning. The present review describes three mechanisms that could theoretically lead to reversible mechanical dysfunction in these patients: myocardial wall stress, the tethering effect, and myocardial expression and release of auto- and paracrine agents. Attention is focused on the role of these mechanisms in scintigraphically "normal" regions (i.e., regions usually showing normal perfusion, glucose metabolism, and cellular integrity as assessed by nuclear imaging techniques), in which stunning is usually considered, but these mechanisms could also operate throughout the viable myocardium. We hypothesize that reversion of these three mechanisms could partially explain the unexpected functional benefit after reperfusion recently highlighted by high-spatial-resolution imaging techniques.

Entities:  

Mesh:

Year:  2006        PMID: 16861690     DOI: 10.1152/ajpheart.01249.2005

Source DB:  PubMed          Journal:  Am J Physiol Heart Circ Physiol        ISSN: 0363-6135            Impact factor:   4.733


  6 in total

1.  Cardiogoniometric parameters for detection of coronary artery disease at rest as a function of stenosis localization and distribution.

Authors:  Thomas Huebner; W M Michael Schuepbach; Andrea Seeck; Ernst Sanz; Bernhard Meier; Andreas Voss; Roland Pilgram
Journal:  Med Biol Eng Comput       Date:  2010-03-19       Impact factor: 2.602

2.  Comparison of cardiogoniometry and ECG at rest versus myocardial perfusion scintigraphy.

Authors:  Stefan Weber; Ralf Birkemeyer; Dominik Schultes; Walter Grewenig; Thomas Huebner
Journal:  Ann Noninvasive Electrocardiol       Date:  2014-03-10       Impact factor: 1.468

Review 3.  Electrocardiologic and related methods of non-invasive detection and risk stratification in myocardial ischemia: state of the art and perspectives.

Authors:  Thomas Huebner; Matthias Goernig; Michael Schuepbach; Ernst Sanz; Roland Pilgram; Andrea Seeck; Andreas Voss
Journal:  Ger Med Sci       Date:  2010-10-11

4.  Equilibrium radionuclide angiography for evaluating the effect of percutaneous coronary intervention on ventricular aneurysm formation and systolic synchrony in patients with acute myocardial infarction.

Authors:  Xue Ling; Fu Xiang-Hua; Liu Jun; Jia Xin-Wei; Wu Wei-Li; Gu Xin-Shun; Ding Chao; Jiang Yun-Fa; Hao Guo-Zhen; Fan Wei-Ze; Zhang Jing
Journal:  Int J Cardiovasc Imaging       Date:  2009-08-12       Impact factor: 2.357

5.  Accuracy of cardiogoniometry compared with electrocardiography in the diagnosis of coronary artery disease.

Authors:  Behshid Ghadrdoost; Majid Haghjoo; Ata Firouzi
Journal:  Res Cardiovasc Med       Date:  2015-02-20

6.  Effects of no-reflow phenomenon on ventricular systolic synchrony in patients with acute anterior myocardial infarction after percutaneous coronary intervention.

Authors:  Le Wang; Gang Liu; Jun Liu; Mingqi Zheng; Liang Li
Journal:  Ther Clin Risk Manag       Date:  2016-06-24       Impact factor: 2.423

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.