The effect of patient age on contrast enhancement during CT of the pancreatobiliary region.

Shigeki Itoh1, Mitsuru Ikeda, Hiroko Satake, Toyohiro Ota, Takeo Ishigaki.   

Abstract

OBJECTIVE: The objective of our study was to assess whether it is possible to reduce the dose and rate of contrast material injection in elderly patients in triple-phase contrast-enhanced CT of the pancreatobiliary region with an MDCT scanner. SUBJECTS AND METHODS: One hundred twelve patients were divided into three groups: contrast injection at 0.08 mL/kg body weight/s (an upper limit of 5 mL/s) over 30 seconds in patients 60 years old or younger (group 1, n = 49), the same contrast injection as group 1 in patients more than 60 years old (group 2, n = 32), and contrast injection at 0.07 mL/kg body weight/s (an upper limit of 4.5 mL/s) over 30 seconds in patients more than 60 years old (group 3, n = 31). Contrast enhancement in the aorta, portal venous system, pancreas, and liver was assessed quantitatively. Two radiologists blinded to the patients' clinical information and the injection protocol used to acquire the CT images graded the degree of contrast enhancement using a 5-point scoring system. The results for the different groups were statistically compared.
RESULTS: Contrast enhancement in the main phases for all organs was significantly more intense in group 2 than in groups 1 and 3. Cases in which pancreatic enhancement in the pancreatic phase was graded as excessive were more frequently observed in group 2. No statistically significant differences were observed between groups 1 and 3 in either quantitative or visual assessment for enhancement of any organ in any phase.
CONCLUSION: We recommend reducing the dose and rate of contrast material injection by at least 10% for elderly patients undergoing MDCT examination of the pancreatobiliary region.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16861556     DOI: 10.2214/AJR.05.0541

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  4 in total

1.  Correlation of abdominal fat ratio with hepatic CT enhancement.

Authors:  Qing Zhang; Mu-Jie Guo; Yu-Fen Wu
Journal:  Exp Ther Med       Date:  2015-05-06       Impact factor: 2.447

2.  The Effect of Contrast Material on Radiation Dose at CT: Part I. Incorporation of Contrast Material Dynamics in Anthropomorphic Phantoms.

Authors:  Pooyan Sahbaee; W Paul Segars; Daniele Marin; Rendon C Nelson; Ehsan Samei
Journal:  Radiology       Date:  2017-01-13       Impact factor: 11.105

3.  Effect of Patient Characteristics on Vessel Enhancement at Lower Extremity CT Angiography.

Authors:  Takanori Masuda; Takeshi Nakaura; Yoshinori Funama; Tomoyasu Sato; Toru Higaki; Masao Kiguchi; Yukari Yamashita; Naoyuki Imada; Kazuo Awai
Journal:  Korean J Radiol       Date:  2018-02-22       Impact factor: 3.500

4.  Effect of Patient Factors on Portal Vein and Hepatic Contrast Enhancement at Computed Tomography Scan With Protocol Combining Fixed Injection Duration and Patients' Body Weight Tailored Dose of Contrast Material.

Authors:  Hui Ye
Journal:  Cureus       Date:  2022-09-18
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.