Literature DB >> 16857502

Capabilities of potential vision test measurements: clinical evaluation in the presence of cataract or macular disease.

Marta Vianya-Estopà1, William A Douthwaite, Bruce A Noble, David B Elliott.   

Abstract

PURPOSE: To determine the usefulness of a battery of potential vision tests (PVTs) including potential acuity meter (PAM), laser interferometer (LI), critical flicker/fusion frequency (CFF), superilluminated pinhole at distance (SPH(d)) and near (SPH(n)), and optimal reading speed (ORS) by their independence of the effects of cataracts and sensitivity to macular disease (MD).
SETTING: Department of Optometry, University of Bradford, Bradford and Leeds General Infirmary, Leeds, United Kingdom.
METHODS: Potential vision test measurements were determined in 76 patients with age-related cataract and no other eye disease, 52 patients with MD and clear ocular media, and 28 patients with normal, healthy eyes.
RESULTS: Potential vision tests were independent of the degrading effects of cataract up to a visual acuity (VA) level of 20/200 or worse (CFF), 20/125 (ORS and SPH), and 20/40 (PAM and LI). A high degree of association was found between PVT scores and distance VA in the MD group for SPH(d) (r2 = 0.93), SPH(n) (r2 = 0.89), and PAM (r2 = 0.71). A moderate correlation was found for LI (r2 = 0.55), CFF (r2 = 0.50), and ORS (r2 = 0.45).
CONCLUSIONS: Potential acuity meter and LI showed very limited independence to moderate/dense cataracts and inaccurate predictions in patients with MD. Superilluminated pinhole was relatively unaffected by moderate/dense cataract and yet provided accurate predictions in the presence of MD and clear ocular media. Critical flicker/fusion frequency showed the greatest ability to bypass cataracts, although its ability to predict VA in patients with early MD was limited. The ORS was relatively unaffected by moderate/dense cataract, but its poor ability to predict VA in MD may limit its clinical suitability as a PVT.

Entities:  

Mesh:

Year:  2006        PMID: 16857502     DOI: 10.1016/j.jcrs.2006.01.111

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  4 in total

Review 1.  [Practical significance of critical fusion frequency (CFF). Chronological resolution of the visual system in differential diagnosis].

Authors:  H Baatz; P Raak; D de Ortueta; A Mirshahi; G Scharioth
Journal:  Ophthalmologe       Date:  2010-08       Impact factor: 1.059

2.  Pupil steering holographic display for pre-operative vision screening of cataracts.

Authors:  Koray Kavaklı; Güneş Aydındoğan; Erdem Ulusoy; Cem Kesim; Murat Hasanreisoğlu; Afsun Şahin; Hakan Urey
Journal:  Biomed Opt Express       Date:  2021-11-23       Impact factor: 3.732

3.  Results of the Pinhole Test Correlate with Hybrid Contact Lens Visual Acuity in Patients with Visual Impairment due to Corneal Diseases.

Authors:  Piotr Kanclerz
Journal:  J Ophthalmol       Date:  2022-06-24       Impact factor: 1.974

4.  Posterior segment causes of reduced visual acuity after phacoemulsification in eyes with cataract and obscured fundus view.

Authors:  Hisham M Jammal; Yousef Khader; Riham Shawer; Muawyah Al Bdour
Journal:  Clin Ophthalmol       Date:  2012-11-07
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.