| Literature DB >> 16855892 |
S R Lubkin1, X Wan.
Abstract
Fluorescence recovery after photobleaching (FRAP) has been widely used to measure fluid flow and diffusion in gels and tissues. It has not been widely used in detection of tissue anisotropy. This may be due to a lack of applicable theory, or due to inherent limitations of the method. We discuss theoretical aspects of the relationship between anisotropy of tissue structure and anisotropy of diffusion coefficients, with special regard to the size of the tracer molecule used. We derive a semi-mechanistic formula relating the fiber volume fraction and ratio of fiber and tracer molecule diameters to the expected anisotropy of the diffusion coefficients. This formula and others are tested on simulated random walks through random simulated and natural media. We determine bounds on the applicability of FRAP for detection of tissue anisotropy, and suggest minimum tracer sizes for detection of anisotropy in tissues of different composition (fiber volume fraction and fiber diameter). We find that it will be easier to detect anisotropy in monodisperse materials than in polydisperse materials. To detect mild anisotropy in a tissue, such as cartilage, which has a low fiber fraction would require a tracer molecule so large that it would be difficult to deliver to the tissue. We conclude that FRAP can be used to detect tissue anisotropy when the tracer molecule is sufficiently large relative to the fiber diameter, volume fraction, and degree of polydispersivity, and when the anisotropy is sufficiently pronounced.Entities:
Mesh:
Substances:
Year: 2006 PMID: 16855892 DOI: 10.1007/s11538-006-9074-z
Source DB: PubMed Journal: Bull Math Biol ISSN: 0092-8240 Impact factor: 1.758