Literature DB >> 16854259

Continuous glucose monitoring by means of fiber-based, mid-infrared laser spectroscopy.

A Lambrecht1, T Beyer, K Hebestreit, R Mischler, W Petrich.   

Abstract

The application of mid-infrared laser spectroscopy to the reagent-free quantification of the concentration of glucose was investigated using cryogenically cooled lead salt lasers or, alternatively, quantum cascade lasers operating at room temperature. The concentration of glucose in aqueous solutions was quantified by means of fiber-based attenuated total reflection (ATR) spectroscopy (fiber-optical evanescent field analysis, FEFA) as well as fiber-based transmission spectroscopy. Both methods have the potential to be utilized by small fiber sensors, which can be inserted into the subcutaneous tissue in order to continuously measure the local concentration of glucose. In our in vitro experiments, noise-equivalent concentrations as low as 10 mg/dL were achieved. The mid-term stability of the measurement schemes was investigated by means of Allan variance analysis. Based on the research presented in this manuscript, an all-room-temperature measurement scheme using quantum cascade lasers, miniaturized fiber-optic sensors, and pyroelectric detectors appears well suited for the continuous monitoring of glucose concentrations at physiological levels.

Entities:  

Mesh:

Year:  2006        PMID: 16854259     DOI: 10.1366/000370206777887071

Source DB:  PubMed          Journal:  Appl Spectrosc        ISSN: 0003-7028            Impact factor:   2.388


  4 in total

1.  Automated blood sampling and glucose sensing in critical care settings.

Authors:  Kislaya Kunjan; Frank P Lloyd
Journal:  J Diabetes Sci Technol       Date:  2008-03

2.  In vitro glucose measurement using tunable mid-infrared laser spectroscopy combined with fiber-optic sensor.

Authors:  Songlin Yu; Dachao Li; Hao Chong; Changyue Sun; Haixia Yu; Kexin Xu
Journal:  Biomed Opt Express       Date:  2013-12-17       Impact factor: 3.732

3.  Cylindrical IR-ATR Sensors for Process Analytics.

Authors:  Armin Lambrecht; Carsten Bolwien; Jochen Erb; Hendrik Fuhr; Gerd Sulz
Journal:  Sensors (Basel)       Date:  2020-05-21       Impact factor: 3.576

4.  Infrared Spectroscopy with a Fiber-Coupled Quantum Cascade Laser for Attenuated Total Reflection Measurements Towards Biomedical Applications.

Authors:  Ine L Jernelv; Karina Strøm; Dag Roar Hjelme; Astrid Aksnes
Journal:  Sensors (Basel)       Date:  2019-11-23       Impact factor: 3.576