Literature DB >> 16849184

Preliminary comparative study of small amplitude helical and conventional ePTFE arteriovenous shunts in pigs.

Colin G Caro1, Nick J Cheshire, Nick Watkins.   

Abstract

Intimal hyperplasia (IH), which causes occlusion of arterial bypass grafts and arteriovenous (A-V) shunts, develops preferentially in low wall shear, or stagnation, regions. Arterial geometry is commonly three-dimensional, generating swirling flows, the characteristics of which include in-plane mixing and inhibition of stagnation. Clinical arterial bypass grafts are commonly two-dimensional, favouring extremes of wall shear. We have developed small amplitude helical technology (SwirlGraft) devices and shown them to generate physiological-type swirling flows. Expanded polytetrafluorethylene (ePTFE) grafts, although widely used as A-V shunts for renal dialysis access, are prone to thrombosis and IH. In a small preliminary study in pigs, we have implanted SwirlGraft ePTFE carotid artery-to-jugular vein shunts on one side and conventional ePTFE carotid artery-to-jugular vein shunts contralaterally. There was consistently less thrombosis and IH in the SwirlGraft than conventional shunts. At eight weeks (two animals), the differences were marked, with virtually no disease in the SwirlGraft devices and occlusion of the conventional grafts by thrombosis and IH. The study had limitations, but the lesser pathology in the SwirlGraft devices is likely to have resulted from their geometry and the associated swirling flow. The results could have implications for vascular biology and prolongation of the patency of arterial bypass grafts and A-V shunts.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16849184      PMCID: PMC1629072          DOI: 10.1098/rsif.2005.0044

Source DB:  PubMed          Journal:  J R Soc Interface        ISSN: 1742-5662            Impact factor:   4.118


  10 in total

Review 1.  Vascular endothelium, hemodynamic forces, and atherogenesis.

Authors:  M A Gimbrone
Journal:  Am J Pathol       Date:  1999-07       Impact factor: 4.307

2.  The influence of out-of-plane geometry on the flow within a distal end-to-side anastomosis.

Authors:  S J Sherwin; O Shah; D J Doorly; J Peiró; Y Papaharilaou; N Watkins; C G Caro; C L Dumoulin
Journal:  J Biomech Eng       Date:  2000-02       Impact factor: 2.097

3.  Mechanosensitive endothelial gene expression profiles: scripts for the role of hemodynamics in atherogenesis?

Authors:  G García-Cardeña; J I Comander; B R Blackman; K R Anderson; M A Gimbrone
Journal:  Ann N Y Acad Sci       Date:  2001-12       Impact factor: 5.691

4.  Anastomotic intimal hyperplasia: mechanical injury or flow induced.

Authors:  H S Bassiouny; S White; S Glagov; E Choi; D P Giddens; C K Zarins
Journal:  J Vasc Surg       Date:  1992-04       Impact factor: 4.268

5.  Distal anastomotic intimal hyperplasia: histopathologic character and biogenesis.

Authors:  V S Sottiurai; J S Yao; R C Batson; S L Sue; R Jones; Y A Nakamura
Journal:  Ann Vasc Surg       Date:  1989-01       Impact factor: 1.466

6.  Atheroma and arterial wall shear. Observation, correlation and proposal of a shear dependent mass transfer mechanism for atherogenesis.

Authors:  C G Caro; J M Fitz-Gerald; R C Schroter
Journal:  Proc R Soc Lond B Biol Sci       Date:  1971-02-16

Review 7.  Flow-mediated endothelial mechanotransduction.

Authors:  P F Davies
Journal:  Physiol Rev       Date:  1995-07       Impact factor: 37.312

8.  Automated classification of peripheral distal by-pass geometries reconstructed from medical data.

Authors:  S Giordana; S J Sherwin; J Peiró; D J Doorly; Y Papaharilaou; C G Caro; N Watkins; N Cheshire; M Jackson; C Bicknall; V Zervas
Journal:  J Biomech       Date:  2005-01       Impact factor: 2.712

9.  Rapid, arteriovenous graft failure due to intimal hyperplasia: a porcine, bilateral, carotid arteriovenous graft model.

Authors:  J I Rotmans; E Velema; H J M Verhagen; J D Blankensteijn; J J P Kastelein; D P V de Kleijn; M Yo; G Pasterkamp; E S G Stroes
Journal:  J Surg Res       Date:  2003-07       Impact factor: 2.192

Review 10.  Mass transport in arteries and the localization of atherosclerosis.

Authors:  John M Tarbell
Journal:  Annu Rev Biomed Eng       Date:  2003-03-19       Impact factor: 9.590

  10 in total
  16 in total

1.  Spiral Laminar Flow is Associated with a Reduction in Disturbed Shear in Patient-Specific Models of an Arteriovenous Fistula.

Authors:  Connor V Cunnane; J Graeme Houston; Daniel T Moran; Stephen P Broderick; Rose A Ross; Michael T Walsh
Journal:  Cardiovasc Eng Technol       Date:  2022-09-23       Impact factor: 2.305

2.  Quantification of near-wall hemodynamic risk factors in large-scale cerebral arterial trees.

Authors:  Mahsa Ghaffari; Ali Alaraj; Xinjian Du; Xiaohong Joe Zhou; Fady T Charbel; Andreas A Linninger
Journal:  Int J Numer Method Biomed Eng       Date:  2018-05-23       Impact factor: 2.747

3.  Oxygen mass transfer in a model three-dimensional artery.

Authors:  G Coppola; C Caro
Journal:  J R Soc Interface       Date:  2008-09-06       Impact factor: 4.118

4.  The effect of in-plane arterial curvature on blood flow and oxygen transport in arterio-venous fistulae.

Authors:  F Iori; L Grechy; R W Corbett; W Gedroyc; N Duncan; C G Caro; P E Vincent
Journal:  Phys Fluids (1994)       Date:  2015-03-17       Impact factor: 3.521

Review 5.  Coronary artery bypass grafting hemodynamics and anastomosis design: a biomedical engineering review.

Authors:  Dhanjoo N Ghista; Foad Kabinejadian
Journal:  Biomed Eng Online       Date:  2013-12-13       Impact factor: 2.819

6.  Fluid-dynamic optimal design of helical vascular graft for stenotic disturbed flow.

Authors:  Hojin Ha; Dongha Hwang; Woo-Rak Choi; Jehyun Baek; Sang Joon Lee
Journal:  PLoS One       Date:  2014-10-31       Impact factor: 3.240

Review 7.  Haemodynamics and Flow Modification Stents for Peripheral Arterial Disease: A Review.

Authors:  Efstratios Kokkalis; Nicolas Aristokleous; J Graeme Houston
Journal:  Ann Biomed Eng       Date:  2015-10-14       Impact factor: 3.934

8.  Numerical Assessment of Novel Helical/Spiral Grafts with Improved Hemodynamics for Distal Graft Anastomoses.

Authors:  Foad Kabinejadian; Michael McElroy; Andres Ruiz-Soler; Hwa Liang Leo; Mark A Slevin; Lina Badimon; Amir Keshmiri
Journal:  PLoS One       Date:  2016-11-18       Impact factor: 3.240

9.  Study of helical flow inducers with different thread pitches and diameters in vena cava.

Authors:  Ying Chen; Xiaoyan Deng; Xinying Shan; Yubin Xing
Journal:  PLoS One       Date:  2018-01-03       Impact factor: 3.240

10.  An immediate access dialysis graft designed to prevent needle-related complications: Results from the initial pre-clinical studies.

Authors:  Shawn M Gage; Michael Lawson; Craig Nichols; Dalton Sycks; Roberto J Manson; Joseph A Knight
Journal:  J Vasc Access       Date:  2019-09-16       Impact factor: 2.283

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.