Literature DB >> 16848268

Detectability of experimental peri-implant cancellous bone lesions using conventional and direct digital radiography.

A Kavadella1, A Karayiannis, K Nicopoulou-Karayianni.   

Abstract

BACKGROUND: The aim of this study was to compare the diagnostic performance obtained from direct digital radiographic images (in their original form and after applying a grey-scale inversion) and conventional film in the detection of artificial peri-implant cancellous bone lesions.
METHODS: Four titanium implants were placed into the cancellous bone of a dry mandible and increasingly larger bone defects were created in their approximal sites. Radiographs were taken using conventional film and a digital charge-coupled device sensor. Twelve observers estimated three series of images (conventional, digital original, digital inverse) on a 5-point confidence scale. Data were evaluated statistically by analysis of variance and the sensitivity, specificity and accuracy of the three imaging modalities were calculated.
RESULTS: Total mean observer confidence scores increased as the size of the defect also increased. No statistically significant differences were found among the three images for the absence of defect and the defect that corresponds to the smallest bur size. Significant differences were found for larger bur sizes between the conventional image and the two digital images and for the largest bur size between the digital inverse and the other two images. Specificity was high and sensitivity relatively low.
CONCLUSIONS: Peri-implant bone lesions must exceed a certain size to be confidently detected but the lesion absence is detected equally well with all three imaging modalities.

Entities:  

Mesh:

Year:  2006        PMID: 16848268     DOI: 10.1111/j.1834-7819.2006.tb00424.x

Source DB:  PubMed          Journal:  Aust Dent J        ISSN: 0045-0421            Impact factor:   2.291


  8 in total

1.  Comparison of accuracy of uncorrected and corrected sagittal tomography in detection of mandibular condyle erosions: an exvivo study.

Authors:  Asieh Zamani Naser; Amir Mansour Shirani; Ehsan Hekmatian; Ali Valiani; Pegah Ardestani; Ava Vali
Journal:  Dent Res J (Isfahan)       Date:  2010

2.  Comparison of Conventional and Standardized Bone Densitometry around Implants in Periapical Radiographs during a Three Months Period.

Authors:  Asieh Zamani Naser; Shahab Etemadi; Mansour Rismanchian; Mahnaz Sheikhi; Mohammadbagher Tavakoli
Journal:  Dent Res J (Isfahan)       Date:  2011

Review 3.  Diagnostic accuracy of imaging examinations for peri-implant bone defects around titanium and zirconium dioxide implants: A systematic review and meta-analysis.

Authors:  Mariana Murai Chagas; Solange Kobayashi-Velasco; Thais Gimenez; Marcelo Gusmão Paraiso Cavalcanti
Journal:  Imaging Sci Dent       Date:  2021-11-18

4.  Effect of digital noise reduction on the accuracy of endodontic file length determination.

Authors:  Mojdeh Mehdizadeh; Abbas Ali Khademi; Ali Shokraneh; Nastaran Farhadi
Journal:  Imaging Sci Dent       Date:  2013-09-23

5.  Diagnostic Accuracy of Inverted and Unprocessed Digitized Periapical Radiographs for Detection of Peri-Implant Defects.

Authors:  Seyed Jalal Pourhashemi; Zahra Ghoncheh; Mohammad Taghi Kiani; Raheleh Emami; Mohamad Javad Kharazifard
Journal:  J Dent (Tehran)       Date:  2015-08

6.  Accuracy of Cone Beam Computed Tomography, Photostimulable Phosphor Plate Digital Radiography and Conventional Radiography for Detection of Artificial Cancellous Bone Defects.

Authors:  Roghieh Bardal; Hassan Jahanihashemi; Maryam Mostafavi; Esmaeil Kalhor; Maryam Tofangchiha; Mahdieh Dehghani
Journal:  J Dent (Tehran)       Date:  2015-11

Review 7.  Using acrylic customized X-ray positioning stents for long-term follow-up studies.

Authors:  Sherif Aly Sadek; Hisham Mohamed Abbas; Moayad Alfelali; Abdulaziz Almahdali
Journal:  Saudi Dent J       Date:  2019-10-15

8.  Intra- and inter-observer agreements in detecting peri-implant bone defects between periapical radiography and cone beam computed tomography: A clinical study.

Authors:  Chu-Nan Zhang; Yu Zhu; Lin-Feng Fan; Xiao Zhang; Yin-Hua Jiang; Ying-Xin Gu
Journal:  J Dent Sci       Date:  2020-11-14       Impact factor: 2.080

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.