Literature DB >> 16847939

Clinical impact of a new automated system employed for peripheral blood stem cell collection.

Claudia Del Fante1, Cesare Perotti, Gianluca Viarengo, Laura Bellotti, Cristina Parisi, Andrea Marchesi, Carmine Tinelli, Laura Salvaneschi.   

Abstract

At the moment, PBSC collections can be performed using semi-automated or automated cell separator devices. The automated methods offer the advantages of a decreased working load for dedicated personnel and high standardization of the collection procedure. Herein we report our single institutional experience in 80 PBSC collections employing the new automated COM.TEC Fresenius autoMNC program that provides the ability to predict the total number of CD34(+) cells collected, based on the pre-leukapheresis CD34(+) cell count in peripheral blood. Fourty-eight patients and 21 healthy donors were mobilized with chemotherapy + G-CSF or G-CSF alone, respectively. Eighty leukapheresis collections were performed starting with a CD34(+) cell count in peripheral blood at least of 20/microL. Collection parameters and related side effects were evaluated. The mean CD34(+) cell collection efficiency in patients and donors was 81.8% (sd 27.6) and 95.1% (sd 15.6), respectively. The mean difference between real and predicted CD34(+) cells was +30.2% (sd 92.9) for patients and +4.6% (sd 30.3) for donors. The mean leukapheresis bag volume was 240.7 ml (sd 67.3) and 310.3 ml (sd 86.8) with a mean HCT of 10.9% (sd 34.4) and 9.2% (sd 3.9) for patients and donors, respectively. The automated PBSC collection with the new program COM.TEC Fresenius autoMNC demonstrated a very high CD34(+) cell collection efficiency. Moreover, the ability to predict the CD34(+) cell yield permits improved management of the leukapheresis collection, with the only disadvantage of larger leukapheresis volume and higher hematocrit.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16847939     DOI: 10.1002/jca.20102

Source DB:  PubMed          Journal:  J Clin Apher        ISSN: 0733-2459            Impact factor:   2.821


  2 in total

1.  A Comparison of Fresenius Com.Tec Cell and Spectra Optia Cell Separators for Autologous and Allogeneic Stem Cell Collections: Single Center Experience.

Authors:  Serife Solmaz; Selda Kahraman; Omur Gokmen Sevindik; Celal Acar; Munire Turkyilmaz; Inci Alacacioglu; Ozden Piskin; Mehmet Ali Ozcan; Hayri Guner Ozsan; Bulent Undar; Fatih Demirkan
Journal:  Indian J Hematol Blood Transfus       Date:  2018-01-23       Impact factor: 0.900

2.  Autologous peripheral blood stem cell harvest: Collection efficiency and factors affecting it.

Authors:  Aseem K Tiwari; Prashant Pandey; Harini Subbaraman; Rahul Bhargava; Ganesh Rawat; Shivani Madiraju; Vimarsh Raina; Richa Bhargava
Journal:  Asian J Transfus Sci       Date:  2016 Jan-Jun
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.