Literature DB >> 16846626

Identification and analysis of multimode guided waves in tibia cortical bone.

De-an Ta1, Kai Huang, Wei-qi Wang, Yuan-yuan Wang, Lawrence H Le.   

Abstract

The hollow cylinder model filled with viscous-liquid is performed to simulate tibial bone shape in this paper. Short time Fourier transform (STFT) was applied to identify and analyze guided wave modes of a series of ultrasonic signals acquired at various transmitter-receiver positions for a fixed transmitter. Experimental results were compared with theoretical simulation. The high correlation values for group velocity were obtained between results of experiment and theory for L(0,2) (r=0.89, p<10(-5)), and L(0,3) (r=0.87, p<10(-5)). The experimental group velocities correlated strongly with cortical thickness (cortTh) for L(0,2) (r(2)=0.79, p<10(-5)) and L(0,3) (r(2)=0.74, p<10(-5)) at 0.5 MHz center frequency. The results showed that the STFT is an effective method to identify the propagating modes and derive dispersion information. The experimental results were in good agreement with theoretical predictions. This study suggests that the guided wave L(0,2) mode is a promising mode to assess change in cortical thickness.

Entities:  

Mesh:

Year:  2006        PMID: 16846626     DOI: 10.1016/j.ultras.2006.06.013

Source DB:  PubMed          Journal:  Ultrasonics        ISSN: 0041-624X            Impact factor:   2.890


  4 in total

1.  Signal Processing Techniques Applied to Axial Transmission Ultrasound.

Authors:  Tho N H T Tran; Kailiang Xu; Lawrence H Le; Dean Ta
Journal:  Adv Exp Med Biol       Date:  2022       Impact factor: 2.622

2.  Axial transmission method for long bone fracture evaluation by ultrasonic guided waves: simulation, phantom and in vitro experiments.

Authors:  Kailiang Xu; Dean Ta; Runxin He; Yi-Xian Qin; Weiqi Wang
Journal:  Ultrasound Med Biol       Date:  2014-01-13       Impact factor: 2.998

3.  Damage Orientation and Depth Effect on the Guided Wave Propagation Behavior in 30CrMo Steel Curved Plates.

Authors:  Chaojie Hu; Bin Yang; Fu-Zhen Xuan; Jianjun Yan; Yanxun Xiang
Journal:  Sensors (Basel)       Date:  2020-02-05       Impact factor: 3.576

4.  Wave dispersion and attenuation on human femur tissue.

Authors:  Maria Strantza; Olivia Louis; Demosthenes Polyzos; Frans Boulpaep; Danny van Hemelrijck; Dimitrios G Aggelis
Journal:  Sensors (Basel)       Date:  2014-08-15       Impact factor: 3.576

  4 in total