Optimal P-wave duration for bedside diagnosis of interatrial block.

Vignendra Ariyarajah1, Sirin Apiyasawat, David H Spodick.   

Abstract

BACKGROUND: Interatrial block (IAB; P wave > or = 110 ms) is highly prevalent and associated with atrial tachyarrhythmias, left atrial electromechanical dysfunction and is a potential risk for embolism. Investigators have often used different parameters for P-wave duration to define IAB, and this causes confusion further adding to clinician ignorance of IAB. We therefore appraised the mode P-wave duration in IAB and evaluated the sensitivity and specificity of using previously used durations.
METHODS: We prospectively evaluated 225 electrocardiograms (ECGs) of patients at a tertiary care general hospital for P-wave duration. Of these, 49 were excluded because of severe motion artifact, errors in lead placement, absence of adequate patient identification, and atrial flutter or fibrillation. Mean, standard error of mean (SEM), standard deviation (SD), mode P-wave duration, specificity, and sensitivity were calculated of the remaining 176 ECGs.
RESULTS: From the sample (N = 176; ages 15-95 years; mean +/- SD = 69.15 +/- 16.53 years, female 50.3%), measured P-wave durations ranged from 50 ms to 230 ms (mean +/- SD = 113.75 +/- 30.56 ms, SEM 2.30 ms). 96 patients (54.55%) showed IAB (P wave > or = 110 ms) with the mode P-wave duration being 120 ms. Sensitivity and specificity of using P wave > or = 110 ms is 100% and 88.9%, respectively (accuracy 94.31%), while P wave > or =130 ms yielded 64% and 100%, respectively (accuracy 82.38%).
CONCLUSIONS: Mode P-wave duration in IAB is 120 ms, and thus, for all practical reasons, it may be used to clinically diagnose IAB using ECGs recorded at the bedside at 25 mm/s with 10 mm/mV standardization.

Entities:  

Mesh:

Year:  2006        PMID: 16846442      PMCID: PMC6932187          DOI: 10.1111/j.1542-474X.2006.00113.x

Source DB:  PubMed          Journal:  Ann Noninvasive Electrocardiol        ISSN: 1082-720X            Impact factor:   1.468


  10 in total

1.  Exceptional prevalence of interatrial block in a general hospital population.

Authors:  U C Jairath; D H Spodick
Journal:  Clin Cardiol       Date:  2001-08       Impact factor: 2.882

2.  Prevalence of interatrial block in a general hospital population.

Authors:  Navaid Asad; David H Spodick
Journal:  Am J Cardiol       Date:  2003-03-01       Impact factor: 2.778

3.  Association of interatrial block with development of atrial fibrillation.

Authors:  Yogesh K Agarwal; Wilbert S Aronow; James A Levy; David H Spodick
Journal:  Am J Cardiol       Date:  2003-04-01       Impact factor: 2.778

4.  COMPLETE INTERATRIAL AND INTRA-ATRIAL BLOCK (ATRIAL DISSOCIATION).

Authors:  J COHEN; D SCHERF
Journal:  Am Heart J       Date:  1965-07       Impact factor: 4.749

Review 5.  Unappreciated prevalence of interatrial block and associated consequences: a poorly perceived pandemic.

Authors:  David H Spodick
Journal:  Mayo Clin Proc       Date:  2004-05       Impact factor: 7.616

6.  Electromechanical dysfunction of the left atrium associated with interatrial block.

Authors:  S B Goyal; D H Spodick
Journal:  Am Heart J       Date:  2001-11       Impact factor: 4.749

7.  Axial correlates of PV1 in left atrial enlargement and relation to intraatrial block.

Authors:  V Velury; D H Spodick
Journal:  Am J Cardiol       Date:  1994-05-15       Impact factor: 2.778

8.  Predictors of atrial fibrillation after conventional and beating heart coronary surgery: A prospective, randomized study.

Authors:  R Ascione; M Caputo; G Calori; C T Lloyd; M J Underwood; G D Angelini
Journal:  Circulation       Date:  2000-09-26       Impact factor: 29.690

9.  Signal-averaged P-wave duration and risk of paroxysmal atrial fibrillation in hyperthyroidism.

Authors:  A Montereggi; P Marconi; I Olivotto; G Castelli; A Dolara; M L Luisi; R G Gheri
Journal:  Am J Cardiol       Date:  1996-02-01       Impact factor: 2.778

Review 10.  Criteria for intraventricular conduction disturbances and pre-excitation. World Health Organizational/International Society and Federation for Cardiology Task Force Ad Hoc.

Authors:  J L Willems; E O Robles de Medina; R Bernard; P Coumel; C Fisch; D Krikler; N A Mazur; F L Meijler; L Mogensen; P Moret
Journal:  J Am Coll Cardiol       Date:  1985-06       Impact factor: 24.094

  10 in total
  3 in total

1.  Atrial electrical activity and atrial fibrillation.

Authors:  Arthur J Moss
Journal:  Ann Noninvasive Electrocardiol       Date:  2006-07       Impact factor: 1.468

2.  P-wave changes in hemodialysis patients: reply to Marano et al.

Authors:  Ramazan Astan; Ozcan Ozeke
Journal:  Ann Noninvasive Electrocardiol       Date:  2014-12-24       Impact factor: 1.468

3.  Interatrial block: a novel risk factor for embolic stroke?

Authors:  Vignendra Ariyarajah; Puneet Puri; Sirin Apiyasawat; David H Spodick
Journal:  Ann Noninvasive Electrocardiol       Date:  2007-01       Impact factor: 1.468

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.