Literature DB >> 16843806

Arthroscopic stabilization of the shoulder: a prospective randomized study of absorbable versus nonabsorbable suture anchors.

Chin Khoon Tan1, Inigo Guisasola, Bhuvaneshwar Machani, Graham Kemp, Christos Sinopidis, Peter Brownson, Simon Frostick.   

Abstract

PURPOSE: The aim of this study was to evaluate, prospectively, outcomes following arthroscopic Bankart repair performed with 2 types of suture anchor--the G II (DePuy Mitek, Raynham, MA) nonabsorbable anchor and the Panalok (DePuy Mitek) absorbable anchor.
METHODS: Patients with a diagnosis of recurrent traumatic anterior instability of the shoulder who were seen in a single unit between April of 2000 and June of 2003 were considered for inclusion in the study. Patients were assessed preoperatively and postoperatively by means of a subjective, patient-related outcome measurement tool (Oxford Instability Score), a visual analogue scale for pain and instability (VAS Pain and VAS Instability), and a quality-of-life questionnaire (Short Form-12 [SF-12]). Length of follow-up was 1.5 to 5 years (mean, 2.6 y). The incidence of recurrent instability and the level of sporting ability were recorded. Patients were randomized to undergo surgical repair with nonabsorbable or absorbable anchors.
RESULTS: A total of 130 patients were included in this study, of whom 6 were lost to follow-up; therefore 124 patients (95%) completed the study. Both types of anchor were highly effective. No differences in rate of recurrence or in any of the scores were noted between the 2 groups. In all, 4 patients in the nonabsorbable group and 3 in the absorbable group experienced additional episodes of dislocation after a traumatic event. Rate of redislocation in the whole series was therefore 6%. In addition, 4 patients, all of them from the absorbable group (4%), described ongoing symptoms of instability but no true dislocations. In all, 85% of the patient group have returned to their previous level of sporting activity.
CONCLUSIONS: No differences in outcomes of arthroscopic Bankart repair were seen whether absorbable or nonabsorbable anchors were used. Both are highly effective, with a redislocation rate of 6%. LEVEL OF EVIDENCE: Level I, therapeutic randomized controlled trial.

Entities:  

Mesh:

Year:  2006        PMID: 16843806     DOI: 10.1016/j.arthro.2006.03.017

Source DB:  PubMed          Journal:  Arthroscopy        ISSN: 0749-8063            Impact factor:   4.772


  24 in total

1.  Comparison between metal and biodegradable suture anchors in the arthroscopic treatment of traumatic anterior shoulder instability: a prospective randomized study.

Authors:  Giuseppe Milano; Andrea Grasso; Domenico A Santagada; Maristella F Saccomanno; Laura Deriu; Carlo Fabbriciani
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2010-07-17       Impact factor: 4.342

2.  A long-term clinical follow-up study after arthroscopic intra-articular Bankart repair using absorbable tacks.

Authors:  Anna Elmlund; Catarina Kartus; Ninni Sernert; Ingrid Hultenheim; Lars Ejerhed
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2008-04-30       Impact factor: 4.342

Review 3.  Risk factors for recurrence after Bankart repair a systematic review.

Authors:  P Randelli; V Ragone; S Carminati; P Cabitza
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-07-27       Impact factor: 4.342

4.  MRI graduation of osseous reaction and drill hole consolidation after arthroscopic Bankart repair with PLLA anchors and the clinical relevance.

Authors:  T Stein; A P Mehling; M Ulmer; C Reck; T Efe; R Hoffmann; A Jäger; F Welsch
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-11-02       Impact factor: 4.342

5.  Results of 45 arthroscopic Bankart procedures: Does the ISIS remain a reliable prognostic assessment after 5 years?

Authors:  Omar Boughebri; Ali Maqdes; Constantina Moraiti; Choukry Dib; Franck Marie Leclère; Philippe Valenti
Journal:  Eur J Orthop Surg Traumatol       Date:  2014-12-06

6.  Metallic versus biodegradable suture anchors for rotator cuff repair: a case control study.

Authors:  Umile Giuseppe Longo; Stefano Petrillo; Mattia Loppini; Vincenzo Candela; Giacomo Rizzello; Nicola Maffulli; Vincenzo Denaro
Journal:  BMC Musculoskelet Disord       Date:  2019-10-25       Impact factor: 2.362

Review 7.  Surgical treatment outcomes after primary vs recurrent anterior shoulder instability.

Authors:  Jonathan D Barlow; Timothy Grosel; John Higgins; Joshua S Everhart; Robert A Magnussen
Journal:  J Clin Orthop Trauma       Date:  2018-10-22

Review 8.  An assessment of quality of randomized controlled trials in shoulder instability surgery using a modification of the clear CLEAR-NPT score.

Authors:  Hassanin Alkaduhimi; Aimane Saarig; Just A van der Linde; Nienke W Willigenburg; Derek F P van Deurzen; Michel P J van den Bekerom
Journal:  Shoulder Elbow       Date:  2018-01-31

9.  Fixation methods and implants in shoulder stabilization: A historical perspective.

Authors:  Jonathan D Kramer; Sean Robinson; Eric Hohn; Connor Purviance; Eugene M Wolf
Journal:  J Orthop       Date:  2018-05-07

10.  Comparison between all-suture and biocomposite anchors in the arthroscopic treatment of traumatic anterior shoulder instability: A retrospective cohort study.

Authors:  Ioannis Pantekidis; Michael-Alexander Malahias; Stefania Kokkineli; Emmanouil Brilakis; Emmanouil Antonogiannakis
Journal:  J Orthop       Date:  2021-03-27
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.