Literature DB >> 16842960

Potentiometric behaviour of ion selective electrodes based on iron porphyrins: the influence of porphyrin substituents on the response properties and analytical determination of diclofenac in pharmaceutical formulations.

Emília M G Santos1, Alberto N Araújo, Cristina M C M Couto, M Conceição B S M Montenegro.   

Abstract

The potentiometric response characteristics of diclofenac selective electrodes based on Fe(III) tetraphenylporphyrin-chloride (Fe(III)TPP-Cl) and Fe(III) tetrakis(pentafluorophenyl)porphyrin-chloride (Fe(III)TPFPP-Cl) in different mediator solvents and ionic additives are compared. The sensitivity, working range, detection limit, response mechanism, and selectivity of the membrane sensor show a significant dependence on the type of carrier substituent and on the pH value of the sample solution. Studies performed with different amounts of cationic additive (tetra-n-octylammoniumbromide (TOABr)) and anionic additive (sodium tetraphenylborate (NaTPB)) in the membranes allowed the determination of the potentiometric mechanism of action of the used metalloporphyrins. For the analysis of real samples, Fe(III)TPFPP-Cl (type G), prepared in o-NPOE, incorporating 10 mol% of TOABr, was used. This potentiometric unit presented a linear response towards diclofenac concentrations between 10(-5) and 10(-2)mol l(-1) ( I=0.1 mol l(-1)) and slopes of about -59 mV dec(-1), exhibiting a response time of 10s in a buffered solution of ammonia-ammonium sulphate with pH 9.9. The potentiometric analysis of sodium diclofenac in pharmaceutical formulations was carried out by direct potentiometry and the obtained results were compared to those provided by HPLC, presenting relative errors inferior to 1.0%.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16842960     DOI: 10.1016/j.jpba.2006.05.019

Source DB:  PubMed          Journal:  J Pharm Biomed Anal        ISSN: 0731-7085            Impact factor:   3.935


  2 in total

1.  Manganese(III) porphyrin-based potentiometric sensors for diclofenac assay in pharmaceutical preparations.

Authors:  Dana Vlascici; Stela Pruneanu; Liliana Olenic; Florina Pogacean; Vasile Ostafe; Vlad Chiriac; Elena Maria Pica; Liviu Calin Bolundut; Luminita Nica; Eugenia Fagadar-Cosma
Journal:  Sensors (Basel)       Date:  2010-09-28       Impact factor: 3.576

2.  Quantification and Classification of Diclofenac Sodium Content in Dispersed Commercially Available Tablets by Attenuated Total Reflection Infrared Spectroscopy and Multivariate Data Analysis.

Authors:  Eirini Siozou; Vasilios Sakkas; Nikolaos Kourkoumelis
Journal:  Pharmaceuticals (Basel)       Date:  2021-05-07
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.