Cyclic loading of Achilles tendon repairs: a comparison of polyester and polyblend suture.

Ross A Benthien1, Michael S Aronow, Vilmaris Doran-Diaz, Raymond J Sullivan, Ryan Naujoks, Douglas J Adams.   

Abstract

BACKGROUND: Early functional rehabilitation is widely used after open suture repair of the Achilles tendon. To our knowledge, no previous studies have assessed gap formation from cyclic loading and subsequent failure loads of simulated Achilles tendon repairs. A synthetic (polyblend) suture has been introduced for tendon repairs with reportedly greater strength than polyester suture. This stronger, stiffer suture material may provide stronger repairs with less elongation of the tendon repair.
METHODS: Simulated Achilles tendon ruptures in bovine Achilles tendon were repaired with a four-strand Krackow suture technique using No. 2 polyester suture. Specimens were loaded for 3,000 cycles at maximal loads of 50, 75, 100, or 125 N, and gap formation at the repair site was continuously measured. After cyclic loading, each specimen was loaded to failure. Identical repairs were performed with number 2 polyblend suture and cyclically loaded to 75 N for 3,000 cycles. All specimens were loaded to failure.
RESULTS: Cyclically loading polyester suture repairs to 50, 75, 100, or 125 N for 3,000 cycles resulted in mean gapping at the repair site of 3.0 +/- 0.8, 4.9 +/- 1.0, 7.2 +/- 0.9, and 7.9 +/- 0.8 mm, respectively. Cyclically loading the polyblend suture repairs for 3,000 cycles at 75 N, resulted in 3.3 +/- 0.3 mm of gap formation at the repair site, significantly less than polyester suture repairs (p < 0.001). The mean load to failure for polyester suture repair was 222 +/- 19 N and for polyblend suture repair was 582 +/- 49 N, a statistically significant difference (p < 0.001). Gap formation at 100, 1,000, and 2,000 cycles, as a percentage of total gap formation at 3,000 cycles, was 64.3%, 87.5%, and 95.4% for polyester suture and 45.8%, 78.5%, and 90.1% for polyblend repairs. All specimens in all groups failed at the knots during load-to-failure testing.
CONCLUSIONS: Cyclic loading of simulated Achilles tendon repairs using a Krackow, four-core polyester suture technique showed progressive gap formation with increasing load. All repairs failed at the knot, and suture pull-out from tendon was not observed. Polyblend suture repair, when compared to identical repairs with braided polyester suture, resulted in a 260% higher load to failure and 33% less gap formation at the repair site after 3,000 cycles. CLINICAL RELEVANCE: The use of polyblend suture in a four-stranded Krackow configuration provides stronger repairs with less gap formation, which may provide increased security during early functional rehabilitation.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16842718     DOI: 10.1177/107110070602700706

Source DB:  PubMed          Journal:  Foot Ankle Int        ISSN: 1071-1007            Impact factor:   2.827


  9 in total

1.  Loop security and tensile properties of polyblend and traditional suture materials.

Authors:  Mehmet Türker; Onder Kılıçoğlu; Ahmet Salduz; Ergun Bozdağ; Emin Sünbüloğlu
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2010-06-10       Impact factor: 4.342

2.  Biomechanical comparison of fixation techniques for medial collateral ligament anatomical augmented repair.

Authors:  Mohamed Omar; Maximilian Petri; Antonios Dratzidis; Simon El Nehmer; Christof Hurschler; Christian Krettek; Michael Jagodzinski; Max Ettinger
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-09-30       Impact factor: 4.342

3.  Proximal Patellar Tendon Repair: Internal Brace Technique With Unicortical Buttons and Suture Tape.

Authors:  George Sanchez; Marcio B Ferrari; Anthony Sanchez; Gilbert Moatshe; Jorge Chahla; Nicholas DePhillipo; Matthew T Provencher
Journal:  Arthrosc Tech       Date:  2017-04-24

4.  Suture anchor repair yields better biomechanical properties than transosseous sutures in ruptured quadriceps tendons.

Authors:  M Petri; A Dratzidis; S Brand; T Calliess; C Hurschler; C Krettek; M Jagodzinski; M Ettinger
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-01-29       Impact factor: 4.342

Review 5.  Achilles tendon rupture: avoiding tendon lengthening during surgical repair and rehabilitation.

Authors:  Javier Maquirriain
Journal:  Yale J Biol Med       Date:  2011-09

6.  Suture-Only Repair Versus Suture Anchor-Augmented Repair for Achilles Tendon Ruptures With a Short Distal Stump: A Biomechanical Comparison.

Authors:  Michael A Boin; Matthew A Dorweiler; Christopher J McMellen; Gregory C Gould; Richard T Laughlin
Journal:  Orthop J Sports Med       Date:  2017-01-04

7.  Tendon end separation with loading in an Achilles tendon repair model: comparison of non-absorbable vs. absorbable sutures.

Authors:  Michael R Carmont; Jan Herman Kuiper; Karin Grävare Silbernagel; Jón Karlsson; Katarina Nilsson-Helander
Journal:  J Exp Orthop       Date:  2017-07-21

8.  Biomechanical Head-to-Head Comparison of 2 Sutures and the Giftbox Versus Bunnell Techniques for Midsubstance Achilles Tendon Ruptures.

Authors:  Rufus O Van Dyke; Sejul A Chaudhary; Gregory Gould; Roman Trimba; Richard T Laughlin
Journal:  Orthop J Sports Med       Date:  2017-05-30

9.  The Biomechanical Properties of a High-Tensile Strength Tape for Tendon Graft Fixation Using the Krackow Configuration.

Authors:  Chih-Kai Hong; Kai-Lan Hsu; Fa-Chuan Kuan; Yueh Chen; Chen-Hao Chiang; Ming-Long Yeh; Miin-Jye Wen; Wei-Ren Su
Journal:  Arthrosc Sports Med Rehabil       Date:  2020-07-09
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.