Literature DB >> 16840391

Reliability, validity, and responsiveness of a 2-min walk test to assess exercise capacity of COPD patients.

Amy S Y Leung1, Kam Keung Chan, Kevin Sykes, K S Chan.   

Abstract

PURPOSES: To investigate the reliability, validity, and responsiveness of a 2-min walk test (2MWT) in Chinese COPD patients with moderate-to-severe disease.
METHODS: This study consisted of two parts. Forty-seven stable COPD patients with moderate-to-severe disease participated in the first part of study for the investigation of reliability and validity. The demographic and anthropomorphic data collected included age, gender, body weight, height, and body mass index. Each subject performed a pulmonary function test, a cardiopulmonary exercise test, three trials of a 2MWT, and two trials of 6-min-walk test (6MWT) in random order within a 5-day period. Fifteen of these subjects participated in the second part of study for the evaluation of the responsiveness of the 2MWT following pulmonary rehabilitation. The 2MWT and 6MWT were conducted before and after the program for comparison.
RESULTS: Forty-five subjects (mean [+/- SD] age, 71.8 +/- 8.3 years; mean FEV1, 0.88 +/- 0.27 L) completed the first part of study, and 9 subjects (mean age, 74 +/- 8.7 years; mean FEV1, 0.94 +/- 0.28 L) completed the second part of study. The intraclass correlation coefficient of the repeated 2MWTs was high (R = 0.9994; p < 0.05), mean differences across trials ranged from 0.3 to 0.8 m (95% confidence interval, -3.1 to 4.6 m) demonstrated its high test-retest reliability. Significant correlations were found between the 2MWT and the 6MWT, the maximum oxygen uptake (V(O2)max) in milliliters per minute, and the V(O2)max in milliliters per kilogram per minute (r = 0.937, 0.454, and 0.555 respectively; p < 0.0125). Following rehabilitation, there were significant improvements in the mean 2MWT and 6MWT walking distance of 17.2 +/- 13.8 m and 60.6 +/- 35.5 m, respectively, with moderate effect sizes (0.61 and 0.53, respectively) and large standardized mean responses (1.25 and 1.70, respectively). High correlation was found between changes in the 2MWT and the 6MWT (r = 0.70; p < 0.05).
CONCLUSION: The 2MWT was shown to be a reliable and valid test for the assessment of exercise capacity and responsive following rehabilitation in patients with moderate-to-severe COPD. It is practical, simple, and well-tolerated by patients with severe COPD symptoms.

Entities:  

Mesh:

Year:  2006        PMID: 16840391     DOI: 10.1378/chest.130.1.119

Source DB:  PubMed          Journal:  Chest        ISSN: 0012-3692            Impact factor:   9.410


  23 in total

1.  Physical therapy management and patient outcomes following ICU-acquired weakness: a case series.

Authors:  Amy Nordon-Craft; Margaret Schenkman; Kyle Ridgeway; Alexander Benson; Marc Moss
Journal:  J Neurol Phys Ther       Date:  2011-09       Impact factor: 3.649

2.  Functional outcomes for clinical trials in frail older persons: time to be moving.

Authors: 
Journal:  J Gerontol A Biol Sci Med Sci       Date:  2008-02       Impact factor: 6.053

3.  Evaluating walking in patients with multiple sclerosis: which assessment tools are useful in clinical practice?

Authors:  Francois Bethoux; Susan Bennett
Journal:  Int J MS Care       Date:  2011

4.  Clinical utility of the 2-minute walk test for older adults living in long-term care.

Authors:  D M Connelly; B K Thomas; S J Cliffe; W M Perry; R E Smith
Journal:  Physiother Can       Date:  2009-05-12       Impact factor: 1.037

5.  A New Clinically Applicable Measure of Functional Status in Patients With Heart Failure: The 60-Foot Walk Test.

Authors:  Kristie M Harris; David S Krantz; Willem J Kop; Joanne Marshall; Shawn W Robinson; Jennifer M Marshall; Stephen S Gottlieb
Journal:  JACC Heart Fail       Date:  2017-05-10       Impact factor: 12.035

6.  Hand grip strength and 2-minute walk test in chronic graft-versus-host disease assessment: analysis from the Chronic GVHD Consortium.

Authors:  Joseph Pidala; Xiaoyu Chai; Paul Martin; Yoshihiro Inamoto; Corey Cutler; Jeanne Palmer; Daniel Weisdorf; Steven Pavletic; Mukta Arora; Madan Jagasia; David Jacobsohn; Stephanie J Lee
Journal:  Biol Blood Marrow Transplant       Date:  2013-03-27       Impact factor: 5.742

7.  A Nontraditional Approach to Cardiac Rehabilitation in the Dialysis Center for a Patient with End-stage Renal Disease Following Coronary Artery Bypass Surgery: A Case Report.

Authors:  Lisa W McVey; Ellen Hillegass
Journal:  Cardiopulm Phys Ther J       Date:  2010-12

8.  Comparison of two- and six-minute walk tests in detecting oxygen desaturation in patients with severe chronic obstructive pulmonary disease - A randomized crossover trial.

Authors:  Rainer Gloeckl; Sebastian Teschler; Inga Jarosch; Jeffrey W Christle; Wolfgang Hitzl; Klaus Kenn
Journal:  Chron Respir Dis       Date:  2016-03-08       Impact factor: 2.444

Review 9.  Patient-reported physical activity questionnaires: a systematic review of content and format.

Authors:  Kate Williams; Anja Frei; Anders Vetsch; Fabienne Dobbels; Milo A Puhan; Katja Rüdell
Journal:  Health Qual Life Outcomes       Date:  2012-03-13       Impact factor: 3.186

10.  The six minute walk test accurately estimates mean peak oxygen uptake.

Authors:  Robert M Ross; Jayasimha N Murthy; Istvan D Wollak; Andrew S Jackson
Journal:  BMC Pulm Med       Date:  2010-05-26       Impact factor: 3.317

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.