Literature DB >> 16839709

Magnetic resonance-guided interstitial therapy for vaginal recurrence of endometrial cancer.

Akila N Viswanathan1, Robert Cormack, Caroline L Holloway, Cynthia Tanaka, Desmond O'Farrell, Phillip M Devlin, Clare Tempany.   

Abstract

PURPOSE: To evaluate the feasibility and to describe the acute toxicity of a real-time intraoperative magnetic resonance (MR)-image guided interstitial approach to treating vaginal recurrence of endometrial cancer. METHODS AND MATERIALS: From February 2004 to April 2005, 10 patients with recurrent endometrial cancer underwent MR-guided interstitial brachytherapy. Parameters evaluated included needle placement, dose-volume histograms (DVH), and complications.
RESULTS: Magnetic resonance-image guidance resulted in accurate needle placement. Tumor DVH values included median volume, 47 cc; V100, 89%; V150, 61%; V200, 38%; D90, 71 Gy; and D100, 60 Gy. DVH of organs at risk resulted in a median D2cc of external beam and brachytherapy dose (% of brachytherapy prescription): bladder, 75Gy(3) (88%); rectum, 70Gy(3) (87%); and sigmoid, 56Gy(3) (41%). All patients experienced either a Grade 1 or 2 acute toxicity related to the radiation; only 1 patient had Grade 3 toxicity. No toxicities were attributable to the use of MR guidance.
CONCLUSIONS: Real-time MR guidance during the insertion of interstitial needles reduces the likelihood of an inadvertent insertion of the needles into the bladder and the rectum. Three-dimensional dosimetry allows estimation of the dose to organs at risk. Toxicities are limited.

Entities:  

Mesh:

Year:  2006        PMID: 16839709     DOI: 10.1016/j.ijrobp.2006.04.037

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  26 in total

Review 1.  Radiation dose-volume effects of the urinary bladder.

Authors:  Akila N Viswanathan; Ellen D Yorke; Lawrence B Marks; Patricia J Eifel; William U Shipley
Journal:  Int J Radiat Oncol Biol Phys       Date:  2010-03-01       Impact factor: 7.038

2.  Comparison of outcomes for MR-guided versus CT-guided high-dose-rate interstitial brachytherapy in women with locally advanced carcinoma of the cervix.

Authors:  Sophia C Kamran; Matthias M Manuel; Linda P Cho; Antonio L Damato; Ehud J Schmidt; Clare Tempany; Robert A Cormack; Akila N Viswanathan
Journal:  Gynecol Oncol       Date:  2017-03-18       Impact factor: 5.482

3.  Prospective Clinical Implementation of a Novel Magnetic Resonance Tracking Device for Real-Time Brachytherapy Catheter Positioning.

Authors:  Jose de Arcos; Ehud J Schmidt; Wei Wang; Junichi Tokuda; Kamal Vij; Ravi T Seethamraju; Antonio L Damato; Charles L Dumoulin; Robert A Cormack; Akila N Viswanathan
Journal:  Int J Radiat Oncol Biol Phys       Date:  2017-06-07       Impact factor: 7.038

4.  Outcomes with image-based interstitial brachytherapy for vaginal cancer.

Authors:  Matthias M Manuel; Linda P Cho; Paul J Catalano; Antonio L Damato; David T Miyamoto; Clare M Tempany; Ehud J Schmidt; Akila N Viswanathan
Journal:  Radiother Oncol       Date:  2016-06-16       Impact factor: 6.280

5.  MR- versus CT-based high-dose-rate interstitial brachytherapy for vaginal recurrence of endometrial cancer.

Authors:  Sophia C Kamran; Matthias M Manuel; Paul Catalano; Linda Cho; Antonio L Damato; Larissa J Lee; Ehud J Schmidt; Akila N Viswanathan
Journal:  Brachytherapy       Date:  2017-08-17       Impact factor: 2.362

6.  Real-time active MR-tracking of metallic stylets in MR-guided radiation therapy.

Authors:  Wei Wang; Charles L Dumoulin; Akila N Viswanathan; Zion T H Tse; Alireza Mehrtash; Wolfgang Loew; Isaiah Norton; Junichi Tokuda; Ravi T Seethamraju; Tina Kapur; Antonio L Damato; Robert A Cormack; Ehud J Schmidt
Journal:  Magn Reson Med       Date:  2014-06-05       Impact factor: 4.668

7.  Use of transrectal ultrasound for high dose rate interstitial brachytherapy for patients of carcinoma of uterine cervix.

Authors:  Daya Nand Sharma; Goura Kisor Rath; Sanjay Thulkar; Sunesh Kumar; Vellaiyan Subramani; Parmod Kumar Julka
Journal:  J Gynecol Oncol       Date:  2010-03-31       Impact factor: 4.401

8.  Sigmoid dose using 3D imaging in cervical-cancer brachytherapy.

Authors:  Caroline L Holloway; Marie-Lynn Racine; Robert A Cormack; Desmond A O'Farrell; Akila N Viswanathan
Journal:  Radiother Oncol       Date:  2009-08-06       Impact factor: 6.280

9.  3-T MR-guided brachytherapy for gynecologic malignancies.

Authors:  Tina Kapur; Jan Egger; Antonio Damato; Ehud J Schmidt; Akila N Viswanathan
Journal:  Magn Reson Imaging       Date:  2012-08-13       Impact factor: 2.546

10.  Dosimetric consequences of interobserver variability in delineating the organs at risk in gynecologic interstitial brachytherapy.

Authors:  Antonio L Damato; Kanopkis Townamchai; Michele Albert; Ryan J Bair; Robert A Cormack; Joanne Jang; Arpad Kovacs; Larissa J Lee; Kimberley S Mak; Kristina L Mirabeau-Beale; Kent W Mouw; John G Phillips; Jennifer L Pretz; Andrea L Russo; John H Lewis; Akila N Viswanathan
Journal:  Int J Radiat Oncol Biol Phys       Date:  2014-05-03       Impact factor: 7.038

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.