Liquid chromatographic-electrospray tandem mass spectrometric determination of clarithromycin in human plasma.

Wenkui Li1, Joan Rettig, Xiangyu Jiang, Diane T Francisco, Weng Naidong.   

Abstract

A rapid, sensitive and specific LC-MS-MS method has been developed for the determination of clarithromycin (CLA) in human plasma using roxithromycin (ROX) as the internal standard. Samples were prepared via liquid-liquid extraction with methyl tert-butyl ether (MTBE) and chromatographed on a Supelco RP(18) (4.6 x 50 mm, 3 microm particle size) column with a mobile phase consisting of acetonitrile:methanol:60 mM (pH 3.5) ammonium acetate buffer (32.5:32.5:35) at a constant flow rate of 0.8 mL/min. The run time was 3 min with retention times of approximately 1.65 and 1.70 min for CLA and ROX, respectively. Detection was performed on a PE Sciex API 365 mass spectrometer equipped with a turboionspray ionization source in multiple reaction monitoring (MRM) mode. The MRM pairs were m/z 748.5 --> m/z 158.2 for CLA and m/z 837.7 --> m/z 679.3 for ROX, respectively, with dwell times of 200 ms for each transition. The validated calibration curve range was 5.00-5000 ng/mL, based on 0.100 mL plasma sample volume with signal-to-noise ratio (S/N) greater than 60 for CLA at the lower limit of quantification level (5.00 ng/mL). The correlation coefficients (r(2)) of the calibration curves were better than or equal to 0.996. The inter-day (n = 18) precision and accuracy of the quality control (QC) samples were less than 3.58% RSD (relative standard deviation) and -10.8% bias, respectively. The intra-day (n = 6) precision and accuracy of the quality control samples were less than 5.0 and 12.6%, respectively. There was no significant deviation from the nominal values after a 10-fold dilution of high concentration QC samples using blank matrix. The QC samples were stable when left on the bench for 24 h or after three freeze-thaw cycles. The processed samples were also stable in HPLC autosampler at 10C for over 72 h. No matrix ionization suppression was observed when extracted blank matrix or reconstitution solvent was injected onto the system with post-column infusion of clarithromycin and roxithromycin. No carryover was observed when an extracted blank plasma sample was injected immediately after a 5000 ng/mL ULOQ (the upper limit of quantification) standard. The mean recovery was 81.5 and 78.3%, respectively, for clarithromycin and internal standard. Copyright (c) 2006 John Wiley & Sons, Ltd.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16838265     DOI: 10.1002/bmc.691

Source DB:  PubMed          Journal:  Biomed Chromatogr        ISSN: 0269-3879            Impact factor:   1.902


  2 in total

1.  Simplified method for determination of clarithromycin in human plasma using protein precipitation in a 96-well format and liquid chromatography-tandem mass spectrometry.

Authors:  Jaekyu Shin; Daniel F Pauly; Julie A Johnson; Reginald F Frye
Journal:  J Chromatogr B Analyt Technol Biomed Life Sci       Date:  2008-07-05       Impact factor: 3.205

2.  Novel microwell assay with high throughput and minimum consumption for organic solvents in the charge transfer-based spectrophotometric determination of clarithromycin in pharmaceutical formulations.

Authors:  Ibrahim A Darwish; Mohammed A Alqarni; Tanveer A Wani
Journal:  Chem Cent J       Date:  2013-10-31       Impact factor: 4.215

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.