Literature DB >> 16835014

Early and long-term prognostic value of Troponin-I after cardiac surgery in newborns and children.

Tomaso Bottio1, Vladimiro Vida, Massimo Padalino, Gino Gerosa, Giovanni Stellin.   

Abstract

BACKGROUND: Troponin-I (Tn-I) is a well-recognized early postoperative marker for myocardial damage in adults and children. The present prospective study was undertaken to investigate whether a postoperative Tn-I value higher than 35 microg/l is able to predict long-term outcome as it does in early postoperative course, after surgery for congenital heart defects (CHD).
MATERIALS AND METHODS: Five hundred and twenty patients (median age 11 months; male 54.7%: 284 patients) undergoing congenital heart defect repair on cardiopulmonary by-pass were prospectively updated in our database including postoperative Tn-I values. Seventy of them (13.4%) (mean age 2.6+/-5.8 months) (70/520) experienced low output syndrome in the early postoperative period. According to the complexity of their malformations, we have arbitrarily divided these patients into two groups: group A included atrial and ventricular septal defects (13 patients), while group B included hypoplastic left heart syndrome, atrio-ventricular canal, transposition of great vessels, tetralogy of Fallot, double outlet right ventricle, truncus arteriosus, total anomalous venous return, and other combined diseases (57 patients). These patients are the object of our study. We reviewed clinical, laboratory, and echocardiographic data performed in the immediate postoperative course (within 24 h) and in the follow-up.
RESULTS: In this study, 13 patients died (13/70 patients; 18.5%), 12 in group B and 1 in group A. In deceased patients, mean Tn-I value was 130+/-175 microg/l (CK-MB 570+/-280 microg/l). Conversely, survivors showed a lower mean Tn-I value (25.5+/-28.9 microg/l; CK-MB 76+/-86 microg/l). Overall, Tn-I peak value was higher than 35 microg/l in 19 patients (19/70; 27.2%); among these, 9 died (median Tn-I was 163+/-186 microg/l), whereas in survivors it was 73.4+/-37 microg/l (p=0.37). The remaining four patients who died had a median Tn-I value of 21 microg/l. When Tn-I exceeded 35 microg/l (>100 microg/l in two cases), at echocardiogram a severely depressed cardiac function was evident. Nevertheless, at long-term follow-up (12+/-6 months), the echocardiogram showed an enhanced cardiac performance with an ejection fraction of 70+/-8.5% in all; none of these patients presented with worsened ventricular function.
CONCLUSION: Cardiac Tn-I is a specific and sensitive marker of myocardial injury after cardiac surgery and it may predict early in-hospital outcomes. However, by long-term echocardiographic analysis, cardiac Tn-I value looses its prognostic significance and therefore it is not a predictor of long-term ventricular dysfunction.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16835014     DOI: 10.1016/j.ejcts.2006.05.001

Source DB:  PubMed          Journal:  Eur J Cardiothorac Surg        ISSN: 1010-7940            Impact factor:   4.191


  12 in total

Review 1.  Is there a rationale for short cardioplegia re-dosing intervals?

Authors:  Yves D Durandy
Journal:  World J Cardiol       Date:  2015-10-26

2.  Cardiac troponin I after cardiopulmonary bypass in infants in comparison with older children.

Authors:  Monesha Gupta-Malhotra; Jeffrey H Kern; Patrick A Flynn; Myles S Schiller; Jan M Quaegebeur; Deborah M Friedman
Journal:  Cardiol Young       Date:  2012-07-20       Impact factor: 1.093

3.  Postoperative Serum Troponin Trends in Infants Undergoing Cardiac Surgery.

Authors:  Jennifer A Su; S Ram Kumar; Hesham Mahmoud; Michael E Bowdish; Omar Toubat; John C Wood; Grace C Kung
Journal:  Semin Thorac Cardiovasc Surg       Date:  2018-09-06

4.  Early pleural effusions related to the myocardial injury after open-heart surgery for congenital heart disease.

Authors:  Monesha Gupta-Malhotra; Jeffrey H Kern; Patrick A Flynn; Myles S Schiller; Jan M Quaegebeur; Deborah M Friedman
Journal:  Congenit Heart Dis       Date:  2010 May-Jun       Impact factor: 2.007

Review 5.  Cardiac injury biomarkers in paediatric age: Are we there yet?

Authors:  Ana L Neves; Tiago Henriques-Coelho; Adelino Leite-Moreira; José C Areias
Journal:  Heart Fail Rev       Date:  2016-11       Impact factor: 4.214

6.  Detection of Early Myocardial Injury in Children with Ventricular Septal Defect Using Cardiac Troponin I and Two-Dimensional Speckle Tracking Echocardiography.

Authors:  Alyaa A Kotby; Manal M Abd Al Aziz; Adel H Husseiny; Marwa M Al-Fahham
Journal:  Pediatr Cardiol       Date:  2020-07-12       Impact factor: 1.655

7.  Comparison of high glucose concentration blood and crystalloid cardioplegia in paediatric cardiac surgery: a randomized clinical trial.

Authors:  Branko Mimic; Slobodan Ilic; Irena Vulicevic; Vladimir Milovanovic; Danijela Tomic; Ana Mimic; Sanja Stankovic; Tatjana Zecevic; Ben Davies; Miroslav Djordjevic
Journal:  Interact Cardiovasc Thorac Surg       Date:  2016-01-31

8.  Early assessment of cardiac troponin I predicts the postoperative cardiac status and clinical course after congenital heart disease surgery.

Authors:  Takuro Kojima; Koichi Toda; Takayuki Oyanagi; Shigeki Yoshiba; Toshiki Kobayashi; Naokata Sumitomo
Journal:  Heart Vessels       Date:  2019-09-14       Impact factor: 2.037

9.  Troponin testing after cardiac surgery.

Authors:  J L Januzzi
Journal:  HSR Proc Intensive Care Cardiovasc Anesth       Date:  2009

10.  Effect of remote ischemic preconditioning on phosphorylated protein signaling in children undergoing tetralogy of Fallot repair: a randomized controlled trial.

Authors:  Salvatore Pepe; Norman Y Liaw; Michele Hepponstall; Freya L Sheeran; Matthew S Yong; Yves d'Udekem; Michael M Cheung; Igor E Konstantinov
Journal:  J Am Heart Assoc       Date:  2013-05-10       Impact factor: 5.501

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.