Literature DB >> 16831542

Detect of Escherichia coli O157:H7 in ground beef samples using piezoelectric excited millimeter-sized cantilever (PEMC) sensors.

Gossett A Campbell1, Joe Uknalis, Shu-I Tu, Raj Mutharasan.   

Abstract

Piezoelectric-excited millimeter-sized cantilever (PEMC) sensors consisting of a piezoelectric and a borosilicate glass layer with a sensing area of 4 mm2 were fabricated. An antibody specific to Escherichia coli (anti-E. coli) O157:H7 was immobilized on PEMC sensors, and exposed to samples containing E. coli O157:H7 (EC) prepared in various matrices: (1) broth, broth plus raw ground beef, and broth plus sterile ground beef without inoculation of E. coli O157:H7 served as controls, (2) 100 mL of broth inoculated with 25 EC cells, (3) 100 mL of broth containing 25 g of raw ground beef and (4) 100 mL of broth with 25 g of sterile ground beef inoculated with 25 EC cells. The total resonant frequency change obtained for the broth plus EC samples were 16+/-2 Hz (n=2), 30 Hz (n=1), and 54+/-2 Hz (n=2) corresponding to 2, 4, and 6h growth at 37 degrees C, respectively. The response to the broth plus 25 g of sterile ground beef plus EC cells were 21+/-2 Hz (n=2), 37 Hz (n=1), and 70+/-2 Hz (n=2) corresponding to 2, 4, and 6 h, respectively. In all cases, the three different control samples yielded a frequency change of 0+/-2 Hz (n=6). The E. coli O157:H7 concentration in each broth and beef samples was determined by both plating and by pathogen modeling program. The results indicate that the PEMC sensor detects E. coli O157:H7 reliably at 50-100 cells/mL with a 3 mL sample.

Entities:  

Mesh:

Year:  2006        PMID: 16831542     DOI: 10.1016/j.bios.2006.05.028

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  4 in total

1.  The Development of a Portable SPR Bioanalyzer for Sensitive Detection of Escherichia coli O157:H7.

Authors:  Shun Wang; Jiufeng Xie; Min Jiang; Keke Chang; Ruipeng Chen; Liuzheng Ma; Juanhua Zhu; Qingqian Guo; Haifeng Sun; Jiandong Hu
Journal:  Sensors (Basel)       Date:  2016-11-04       Impact factor: 3.576

Review 2.  Overview of Piezoelectric Biosensors, Immunosensors and DNA Sensors and Their Applications.

Authors:  Miroslav Pohanka
Journal:  Materials (Basel)       Date:  2018-03-19       Impact factor: 3.623

3.  A V-Shaped Microcantilever Sensor Based on a Gap Method for Real-Time Detection of E. coli Bacteria.

Authors:  Jino Fathy; Yongjun Lai
Journal:  Biosensors (Basel)       Date:  2022-03-25

Review 4.  The Recent Progress of MEMS/NEMS Resonators.

Authors:  Lei Wei; Xuebao Kuai; Yidi Bao; Jiangtao Wei; Liangliang Yang; Peishuai Song; Mingliang Zhang; Fuhua Yang; Xiaodong Wang
Journal:  Micromachines (Basel)       Date:  2021-06-19       Impact factor: 2.891