Literature DB >> 16830720

A model of flow-through pore formation in methacrylate ester-based monolithic columns.

Jirí Urban1, Dana Moravcová, Pavel Jandera.   

Abstract

The main factors affecting the porosity of methacrylate-ester based monolithic columns were investigated. We prepared 23 monolithic capillary columns with porosity controlled by varying the proportions of butyl methacrylate and ethylene dimethacrylate monomers and of 1,4-butanediol and 1-propanol as the porogen solvent in the polymerization mixtures by thermally initiated in-situ polymerization in fused-silica capillaries. Using mixture design software, we systematically varied the composition of the polymerisation mixtures to find significant factors affecting flow-through pore formation. Multivariate analysis of the experimental data obtained for the fabricated columns yielded a model for prediction of the flow-through porosity in monolithic beds as a function of the composition of the polymerization mixture used to prepare polymethacrylate monolithic capillary columns. The mean error of prediction was lower than 8% for eight columns prepared independently of the original set of 15 columns used to derive the flow-through model. The flow-through porosity increases with increasing concentration of the binary porogen solvent mixture, the concentration of 1,4-butanediol being the main factor enhancing flow-through pore formation. On the other hand, increasing concentrations of the hydrophobic monomer butyl methacrylate and increasing concentrations of 1-propanol have a negative effect on flow-through pore formation. The capillary columns prepared with a high proportion of flow-through pores and a minimum amount of mesopores can be used for fast gradient separations of both low-molecular weight compounds and biopolymers.

Entities:  

Year:  2006        PMID: 16830720     DOI: 10.1002/jssc.200500457

Source DB:  PubMed          Journal:  J Sep Sci        ISSN: 1615-9306            Impact factor:   3.645


  3 in total

1.  Hypercrosslinking: new approach to porous polymer monolithic capillary columns with large surface area for the highly efficient separation of small molecules.

Authors:  Jiri Urban; Frantisek Svec; Jean M J Fréchet
Journal:  J Chromatogr A       Date:  2010-10-31       Impact factor: 4.759

2.  Efficient separation of small molecules using a large surface area hypercrosslinked monolithic polymer capillary column.

Authors:  Jiri Urban; Frantisek Svec; Jean M J Fréchet
Journal:  Anal Chem       Date:  2010-03-01       Impact factor: 6.986

3.  Reversed-phase ion-pair liquid chromatography electrospray ionization tandem mass spectrometry for separation, sequencing and mapping of sites of base modification of isomeric oligonucleotide adducts using monolithic column.

Authors:  Vaneet K Sharma; James Glick; Paul Vouros
Journal:  J Chromatogr A       Date:  2012-05-09       Impact factor: 4.759

  3 in total