Literature DB >> 16830560

Estimation of the uptake rate constants for polycyclic aromatic hydrocarbons accumulated by semipermeable membrane devices and triolein-embedded cellulose acetate membranes.

Runhui Ke1, Yiping Xu, Zijian Wang, Shahamat U Khan.   

Abstract

In this paper we report an extension of our previous work on the triolein-embedded cellulose acetate membrane (TECAM) as a passive sampling device (PSD) and describe the results from simultaneous exposure of TECAMs and triolein-containing semipermeable membrane devices (SPMDs) to PAHs in lake water for 16 days. The data obtained provided a comparison of the uptake rates of specific PAHs by the two PSDs. Using 16-day accumulation tests, similar PAH distribution patterns in TECAMs and in SPMDs (R2 = 0.89, p < 0.0001) were observed. However, it was noted that TECAMs could take up greater amounts of PAHs than SPMDs (735 ng/g of TECAM vs 630 ng/g of SPMD). Uptake rate constants of TECAMs and SPMDs for 16 priority pollutant (PP) PAHs, corrected for dissolved organic carbon, ranged from 0.28 to 2.94 L d(-1) and from 0.16 to 0.91 L d(-1), respectively. The elimination rate constants of TECAMs were 1.4-6.7 times greater than those observed for SPMDs, thereby indicating that PAHs required shorter times to achieve equilibrium in TECAMs than in SPMDs. Thus, the results of the present study suggest that TECAMs have significant potential as a good monitor to assess the pollution of hydrophobic pollutants in aquatic environments.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16830560     DOI: 10.1021/es060493t

Source DB:  PubMed          Journal:  Environ Sci Technol        ISSN: 0013-936X            Impact factor:   9.028


  3 in total

1.  Application of the triolein-embedded cellulose acetate membrane passive sampler for monitoring of polycyclic aromatic hydrocarbons in water.

Authors:  Jianfeng Tang; Guiying He; Gang Li
Journal:  Environ Sci Pollut Res Int       Date:  2014-05-27       Impact factor: 4.223

2.  Aquatic passive sampling of perfluorinated chemicals with polar organic chemical integrative sampler and environmental factors affecting sampling rate.

Authors:  Ying Li; Cunman Yang; Yijun Bao; Xueru Ma; Guanghua Lu; Yi Li
Journal:  Environ Sci Pollut Res Int       Date:  2016-05-05       Impact factor: 4.223

3.  Polymer coating of paramagnetic particulates for in vivo oxygen-sensing applications.

Authors:  Edward Eteshola; Ramasamy P Pandian; Stephen C Lee; Periannan Kuppusamy
Journal:  Biomed Microdevices       Date:  2009-04       Impact factor: 2.838

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.